Potential of CO2 emission reduction via application of geothermal heat exchanger and passive cooling in residential sector under Polish climatic conditions.
Author(s) : FIDORÓW-KAPRAWY N., STEFANIAK Ł.
Type of article: Periodical article
Summary
The article summarizes the results of the 25-year time horizon performance analysis of the ground source heat pump that serves as a heat source in a detached house in the climatic conditions that prevail in Wrocław, Poland. The main aim is to assess the potential of ground regeneration and reduction of CO2 emission by passive cooling application. The study adds value to similar research conducted worldwide for various conditions. The behavior of the lower source of the heat pump was simulated using EED software. The ground and borehole properties, heat pump characteristics, heating and cooling load, as well as the energy demand for domestic hot water preparation have been used as input data. Based on the brine temperatures for all analyzed cases including the ground with lower and higher values of conductivity and heat capacity, the borehole filler of inferior and superior thermal properties, and the passive cooling option turned on and off, the seasonal efficiencies of the heat pump have been calculated. The energy and emission savings calculations are based on the values obtained. The application of passive cooling reduces the brine temperature drop by 0.5 K to over 1.0 K in consecutive years in the analyzed cases and the thermal imbalance by 65.0% to 65.9%. Electric energy savings for heating and domestic hot water preparation reach 4.5%, but the greatest advantage of the system is the possibility of almost emission-free colling the living spaces which allows reducing around 33.7 GWh of electric energy and 1186–1830 kg of CO2 emission for cooling.
Available documents
Format PDF
Pages: 15 p.
Available
Free
Details
- Original title: Potential of CO2 emission reduction via application of geothermal heat exchanger and passive cooling in residential sector under Polish climatic conditions.
- Record ID : 30030957
- Languages: English
- Subject: Technology, Environment
- Source: Energies - vol. 15 - n. 22
- Publishers: MDPI
- Publication date: 2022/11
- DOI: http://dx.doi.org/https://doi.org/10.3390/en15228531
Links
See other articles in this issue (13)
See the source
-
Case study of the largest air source heat pumps...
- Author(s) : ZHAO M., WANG H., ZHAO H., XIE S, NI L.
- Date : 2023/05/15
- Languages : English
- Source: 14th IEA Heat Pump Conference 2023, Chicago, Illinois.
- Formats : PDF
View record
-
CO2 emission savings of heat pumps i...
- Author(s) : ROMANO E., FRAGA C., HOLLMULLER P.
- Date : 2021/08/31
- Languages : English
- Source: 13th IEA Heat Pump Conference 2021: Heat Pumps – Mission for the Green World. Conference proceedings [full papers]
- Formats : PDF
View record
-
Heat pumps in existing residential buildings.
- Author(s) : MIARA M., GÜNTHER D., LANGNER R.
- Date : 2021/08/31
- Languages : English
- Source: 13th IEA Heat Pump Conference 2021: Heat Pumps – Mission for the Green World. Conference proceedings [full papers]
- Formats : PDF
View record
-
Thermal Impact by Open-Loop Geothermal Heat Pum...
- Author(s) : PERMANDA R., OHTANI T.
- Date : 2022/09
- Languages : English
- Source: Energies - vol. 15 - n. 18
- Formats : PDF
View record
-
Ispitivanje karakteristika sistema i rekonstruk...
- Author(s) : CUI P., AN H., JIANG H.
- Date : 2016/12
- Languages : English
- Source: 47th International HVAC&R Congress and Exhibition.
- Formats : PDF
View record