Prediction of capillary tubes with alternative refrigerants to CFC-502.
Author(s) : SAMI S. M., DESJARDINS D. E., et al.
Type of article: Article
Summary
This article presents a numerical model for predicting the performance of capillary tubes using new alternative refrigerants to R502. The model was established in accordance with the fluid flow conservation equation written for a homogeneous azeotropic refrigerant fluid flow under saturated, subcooled and two-phase conditions. The study was limited to the azeotropic mixtures R507, R404A and the quaternary mixture (R32/R125/R134a/R143a).
Details
- Original title: Prediction of capillary tubes with alternative refrigerants to CFC-502.
- Record ID : 2004-1130
- Languages: English
- Source: Int. J. Energy Res. - vol. 25 - n. 14
- Publication date: 2001/11
Links
See other articles in this issue (1)
See the source
Indexing
-
Numerical prediction of capillary tube behaviou...
- Author(s) : SAMI S. M., TRIBES C.
- Date : 1998/06
- Languages : English
- Source: Applied Thermal Engineering - vol. 18 - n. 6
View record
-
Numerical simulation of capillary-tube expansio...
- Author(s) : GARCÍA-VALLADARES O., PÉREZ-SEGARRA C. D., OLIVA A.
- Date : 2002/03
- Languages : English
- Source: Applied Thermal Engineering - vol. 22 - n. 4
View record
-
Experimental analysis of capillary tubes behavi...
- Author(s) : SAMI S. M., MALTAIS H.
- Date : 2001/11
- Languages : English
- Source: Int. J. Energy Res. - vol. 25 - n. 14
View record
-
Proces dlawienia dwufazowych czynników chlodnic...
- Author(s) : FLOREK R., KRÓLICKI Z.
- Date : 2001
- Languages : Polish
- Source: Chlodnictwo - vol. 36 - n. 12
View record
-
Expansieorganen-leverancierregister.
- Date : 1998/07
- Languages : Dutch
- Source: Koude & Luchtbehandeling - suppl.; poster; 1 tabl.
View record