IIR document
Pressure loss and performance assessment of horizontal spiral coil inserted pipes during forced convective evaporation of R-600a.
Author(s) : ALIMARDANI F., AHMADI H., SARMADIAN A., et al.
Type of article: Article, IJR article
Summary
The impacts of spiral coil inserts on the pressure loss of environment-friendly refrigerant R-600a are experimentally evaluated during forced convective evaporation within horizontal copper pipes. Then, by considering the current pressure drop and previous heat transfer results and calculating the performance factor, the overall effectiveness of the inserts is determined. Experiments are carried out for smooth and rough tubes. Five spiral coils with various coil pitches and wire diameters are utilized. Also, vapor qualities between 0.08 and 0.7 and mass fluxes between 109.2 and 505 kg m -2 s -1 are considered for tests. Generally, it is observed that inserts augment the pressure loss in the range of 90–958% over the smooth pipe. However, as the wire diameter decreases and the coil pitch increases, less pressure losses are im- posed to the system. Depending on the operational conditions and inserts type, the performance factor was obtained between 0.13 and 1.40. The coiled wire “CW5”with the wire diameter of 1 mm and coil pitch of 30 mm performed superior compared to the other inserts by maximum performance factor of 1.4. Finally, by using the current data a new correlation is proposed in order to predict the evaporative pressure loss of R-600a within spiral coil inserted pipes.
Available documents
Format PDF
Pages: 20-30
Available
Public price
20 €
Member price*
Free
* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).
Details
- Original title: Pressure loss and performance assessment of horizontal spiral coil inserted pipes during forced convective evaporation of R-600a.
- Record ID : 30026960
- Languages: English
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 107
- Publication date: 2019/11
- DOI: http://dx.doi.org/10.1016/j.ijrefrig.2019.08.016
Links
See other articles in this issue (32)
See the source
Indexing
-
Prediction of effective friction factors for si...
- Author(s) : WANG H. S., ROSE J. W.
- Date : 2004/12
- Languages : English
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 27 - n. 8
- Formats : PDF
View record
-
A study on the flow characteristics of refriger...
- Author(s) : KIM H. S., YOON P. H., SA Y. C., et al.
- Date : 2014/12
- Languages : English
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 48
- Formats : PDF
View record
-
CALCUL DES PERTES DE CHARGE.
- Author(s) : SLAMA B.
- Date : 1990/06
- Languages : French
- Source: Chaud Froid Plomb. - vol. 44 - n. 515
View record
-
Developing flow correlations for different valv...
- Author(s) : STULGIES N., KÖHLER J., TEGETHOFF W., et al.
- Date : 2008/05
- Languages : English
- Source: HVAC&R Research - vol. 14 - n. 3
View record
-
Experimental investigation of pressure drop dur...
- Author(s) : GARCIA PABON J. J., KHOSRAVI A., NUNES R., et al.
- Date : 2019/08
- Languages : English
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 104
- Formats : PDF
View record