Removing of micropollution in air-conditioning and ventilation systems by means of cyclones supplied with an electrical field.
Usuwanie zanieczyszczen o wymiarach mikronowych z ukladow klimatyzacyjno-wentylacyjnych z wykorzystaniem cyklonow z polem elektrycznym.
Author(s) : LACKOWSKI M., KARWACKI J., BUTRYMOWICZ D., et al.
Type of article: Article, Review
Summary
Removing of micropollution may be thought as a very important issue for air-conditioning and ventilation systems because of health hazard caused by microorganisms and dust. Cyclones are the cheapest and the least troublesome solution to the above problem. Application of electric field in these devices can improve micropollution separation efficiency which is the most difficult to achieve. A close attention has been paid to the economic consequences of the application of the cyclones with and without electric field supply. The results of the analysis have been presented in tables.
Available documents
Format PDF
Pages: 392-396
Available
Public price
20 €
Member price*
15 €
* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).
Details
- Original title: Usuwanie zanieczyszczen o wymiarach mikronowych z ukladow klimatyzacyjno-wentylacyjnych z wykorzystaniem cyklonow z polem elektrycznym.
- Record ID : 2009-1239
- Languages: Polish
- Source: Technika Chlodnicza i Klimatyzacyjna - vol. 14 - n. 10
- Publication date: 2007/10
Links
See other articles in this issue (2)
See the source
Indexing
- Themes: Other air-conditioning equipment
- Keywords: Centrifugation; Ventilation; Review; Separation; Pollution; Cleaning; Air conditioning
-
FILTRATION : LA REPONSE DU FILTRE A L'ATMOSPHERE.
- Date : 1991
- Languages : French
- Source: La revue pratique du froid et du conditionnement d'air - vol. 46 - n. 734
View record
-
Le condotte aerauliche: bonifica e sanificazione.
- Author(s) : SCIORTINO G., BETTINELLI D.
- Date : 2000/10
- Languages : Italian
- Source: Cond. Aria - vol. 44 - n. 10
View record
-
Ventilation and IAQ with total enthalpy ERV fix...
- Author(s) : HUTSON P.
- Date : 2009/01
- Languages : English
- Source: IRHACE J. - vol. 21 - n. 1
View record
-
NOXIOUS GASES AND THEIR CONTROL BY CHEMICAL FIL...
- Author(s) : MCKERNAN I. W.
- Date : 1988/03
- Languages : English
- Source: H&V Eng. - vol. 61 - n. 687
View record
-
Metody i procedury czyszczenia przewodów wentyl...
- Author(s) : CHARKOWSKA A.
- Date : 2004/05
- Languages : Polish
- Source: Technika Chlodnicza i Klimatyzacyjna - vol. 11 - n. 5
- Formats : PDF