Research on the heat transfer experiment of R245fa.

[In Chinese. / En chinois.]

Author(s) : LUO C., GONG Y., MA W. B.

Type of article: Article

Summary

The heat transfer performance of evaporator and condenser is the key factor which has an effect on the power efficiency in the refrigeration and power generation units. An experimental investigation of evaporator and condenser heat transfer with different inlet and outlet hot water temperature was conducted. The cycle working fluid was R245fa. The experiment showed that the evaporator heat transfer coefficient decreased and condenser heat transfer coefficient increased first and then decreased with increasing inlet hot water temperature. The higher heat water temperature, the higher evaporation pressure; and the evaporator heat transfer coefficient can reach to 2500 W / ( m2.°C).

Available documents

Format PDF

Pages: 21-25

Available

  • Public price

    20 €

  • Member price*

    15 €

* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).

Details


Links


See other articles in this issue (5)
See the source