RESULTS OF THE RESIDENTIAL EARTH-COUPLED HEAT PUMP DEMONSTRATION IN UPSTATE NEW YORK.
Author(s) : HUGHES P. J.
Summary
THE DEMONSTRATION HAS SHOWN THAT COMMERCIALLY AVAILABLE RESIDENTIAL EARTH-COUPLED HEAT PUMP SYSTEMS PERFORM WELL IN THE NORTHERN CLIMATE AND SOIL CHARACTERISTICS OF UPSTATE NEW YORK. THE INDUSTRY EARTH LOOP SIZING RULES OF THUMB SEEM APPROPRIATE IN THIS REGION. ELECTRICAL DEMAND CHARACTERISTICS OF THE TECHNOLOGY ARE ALSO ATTRACTIVE. THE VARIABILITY OF SITE CONDITIONS AND CONTRACTOR EXPERIENCE CAUSES UNCERTAINTY IN THE INSTALLED COST OF EARTH LOOPS.
Details
- Original title: RESULTS OF THE RESIDENTIAL EARTH-COUPLED HEAT PUMP DEMONSTRATION IN UPSTATE NEW YORK.
- Record ID : 1987-0296
- Languages: English
- Publication date: 1985
- Source: Source: ASHRAE Trans.
vol. 91; n. 2B; 1307-1325; 5 fig.; 9 tabl.; 1 ref. - Document available for consultation in the library of the IIR headquarters only.
Indexing
-
Themes:
Heat pumps techniques;
Residential heat-pumps - Keywords: Hot water; Profitability; Ground; Heat pump; Performance; Residential building; USA
-
OUTDOOR AIR AND THE GROUND AS HEAT SOURCE FOR H...
- Author(s) : JENSEN L., WETTERSTAD L.
- Date : 1985
- Languages : Swedish
- Source: Swed. Counc. Build. Res. - R89:1985; 123 p.
View record
-
IS A HEAT PUMP PLANT WORTHWHILE.
- Author(s) : HEGELE M.
- Date : 1984
- Languages : German
- Source: Sonnenenerg. Wärmepumpe - vol. 9 - n. 2
View record
-
BEFORE AND AFTER METERED DATA AND DAILY LOAD PR...
- Author(s) : LLOYD A. S., KOHLOSS F. H., ELLIOTT S. P.
- Date : 1985
- Languages : English
View record
-
EXPERIMENTALLY DERIVED ENERGETISTIC EFFICIENCY ...
- Author(s) : SUKIENNIK M. A.
- Date : 1986/08/05
- Languages : English
- Source: Progress in the design and construction of refrigeration systems.
- Formats : PDF
View record
-
WATER-LOOP HEAT PUMP SYSTEMS ASSESSMENT.
- Author(s) : PIETSCH J. A.
- Date : 1990
- Languages : English
View record