Simulation of in-line versus staggered arrays of vented pallet boxes for assessing cooling performance of orange in cool storage.
Author(s) : SAJADIYE S. M., ZOLFAGHARI M.
Type of article: Article
Summary
The cooling performance of fruits and vegetables including transient heat removal, temperature homogeneity and moisture loss inside the cool storages is affected by pallet boxes arrangement. In this paper, the effect of two different types of vented pallet boxes arrangement including in-line and staggered on cooling performance were compared while longitudinal gaps between the pallet boxes and cooling airflow varied at three commonly applied levels. Validated computational fluid dynamics (CFD) models of airflow, heat and mass transfer were applied as an alternative for the experiments. Results showed that staggered array increased the surface heat transfer coefficient at the pallet boxes wall from 18% to 53%, which caused 28% to 38% reduction in ¾ cooling time compared to in-line. The most effectiveness of staggered array on heat transfer coefficient occurred for 0.25 m longitudinal gap between the pallet boxes. Staggered array did not improve temperature homogeneity and moisture loss. Results also showed that, an increment of longitudinal gaps from 0.1 to 0.25 m caused 10% reduction in ¾ cooling time. Increasing more than 0.25 m, did not showed reasonable improvement in cooling performance.
Details
- Original title: Simulation of in-line versus staggered arrays of vented pallet boxes for assessing cooling performance of orange in cool storage.
- Record ID : 30021169
- Languages: English
- Source: Applied Thermal Engineering - vol. 115
- Publication date: 2017/03/25
- DOI: http://dx.doi.org/10.1016/j.applthermaleng.2016.12.063
Links
See other articles in this issue (31)
See the source
Indexing
-
The beam heat exchange of the refrigerator wall...
- Author(s) : MIRONTCHUK Û. A.
- Date : 2009
- Languages : Russian
- Source: Holodil'na Tehnika i Tehnologiâ - n. 1
View record
-
FOUNDATIONS AND SUPERSTRUCTURE SYSTEMS FOR STAC...
- Author(s) : SHAFFER J. A.
- Date : 1983
- Languages : English
View record
-
Effective heat insulation for cold stores roofing.
- Author(s) : KORNIENKO V. N., CHERNYAK V. A., SHUGAEV A. V.
- Date : 2014
- Languages : Russian
- Source: Kholodilnaya Tekhnika - n. 7
View record
-
QUALITY CONTROL OF COLD STORE ASSEMBLING BY INF...
- Author(s) : GRINZATO E. G.
- Date : 1990/09/24
- Languages : English
- Formats : PDF
View record
-
DETERMINATION OF THE RESISTANCE TO HEAT TRANSFE...
- Author(s) : FAJNSTEJN V. A.
- Date : 1985
- Languages : Russian
- Source: Kholodilnaya Tekhnika - n. 5
View record