Simulation study on the performance of constant and variable cooling water flow under part load for a scroll chiller.
Author(s) : JIN X., ZHANG X. S.
Summary
The chillers are usually loaded partly in the most of running times, and with the development of variable frequency technology, more and more variable-frequency compressors and pumps are used in refrigeration and air-conditioning systems. The steady-state model of the refrigeration cycle is built in this paper, in which the RKS equation is used to calculate the thermophysical parameters accurately. The results show that the influences of constant or variable water flow to the evaporating temperature are little when the chiller is loaded partly, but the condensing temperature decreases in different degrees. The power consumption proportion of the cooling water pump in the chiller should be considered in evaluating energy-saving effect of constant or variable water flow. The higher the proportion, the better the effect of energy-saving of variable water flow system.
Details
- Original title: Simulation study on the performance of constant and variable cooling water flow under part load for a scroll chiller.
- Record ID : 2009-0305
- Languages: English
- Source: Cryogenics and refrigeration. Proceedings of ICCR'2008.
- Publication date: 2008/04/05
Links
See other articles from the proceedings (170)
See the conference proceedings
Indexing
- Themes: Other air-conditioning equipment
- Keywords: Variable volume; Chiller; Simulation; Modelling; Air conditioning; Water; Scroll compressor
-
Modelling the performance of single-duct VAV sy...
- Author(s) : DAVIS M. A., BRYANT J. A., O'NEAL D. L., et al.
- Date : 2009/01/25
- Languages : English
- Source: ASHRAE Transactions. Papers presented at the 2009 ASHRAE Winter Conference: Chicago, Illinois, January 2009. Volume 115, part 1.
View record
-
Simulation of floating condensing temperature c...
- Author(s) : YU F. W., CHAN K. T.
- Date : 2006/05/21
- Languages : English
- Source: ACRA-2006. Proceedings of the 3rd Asian conference on refrigeration and air conditioning.
View record
-
Experimental verification of a three zone VAV s...
- Author(s) : BRYANT J. A., DAVIS M. A., O'NEAL D. L., et al.
- Date : 2009/01/25
- Languages : English
- Source: ASHRAE Transactions. Papers presented at the 2009 ASHRAE Winter Conference: Chicago, Illinois, January 2009. Volume 115, part 1.
View record
-
Parametric analysis of a building space conditi...
- Author(s) : ZHANG Z., NELSON R. M.
- Date : 1992
- Languages : English
View record
-
A dynamic model of a multizone VAV system for c...
- Author(s) : ZAHEER-UDDIN M., ZHENG G. R.
- Date : 1994
- Languages : English
- Source: Heat pumps in cold climates. Proceedings of the second international technical conference.
View record