Study of expediency conditions of thermal wave phase shift in thermal insulation of cold rooms.

[In Russian. / En russe.]

Author(s) : MIRONTCHUK Û. A.

Type of article: Article

Summary

In climatic zones with a high amplitude in the daily temperature fluctuations of atmospheric air, the massive thermal insulation of cold rooms has advantages vs. sandwich panels. With the exception of simplification of conditions of maintenance of a required temperature mode in cold rooms, the opportunity to lower (by 30-40%) the established productivity of cold and power consumption of the compressor equipment was achieved and the areas of heat exchangers were lowered by 20-30%; a simultaneous decrease of 10% of current power consumption used to compensate heat inflows through wall protection was demonstrated.

Details

  • Original title: [In Russian. / En russe.]
  • Record ID : 2005-2135
  • Languages: Russian
  • Source: Holodil'na Tehnika i Tehnologiâ - n. 3
  • Publication date: 2004

Links


See other articles in this issue (23)
See the source