STUDY ON AIR VELOCITY DISTRIBUTION IN CONVENTIONAL FLOW TYPE CLEAN ROOM. 3. NUMERICAL STUDY ON FLOW FIELD AND DIFFUSION FIELD AFFECTED BY LOCATION OF SUPPLY OUTLETS AND EXHAUST INLETS.
[In Japanese. / En japonais.]
Author(s) : MURAKAMI S., KATO S., SUYAMA Y.
Type of article: Article
Summary
AIR FLOW AND CONTAMINANT DIFFUSION IN SEVERAL TYPES OF CONVENTIONAL FLOW-TYPE CLEAN ROOM MODELS WERE STUDIED BY MEANS OF NUMERICAL SIMULATION. THE INFLUENCE OF THE LOCATION OF SUPPLY OUTLETS AND EXHAUST INLETS ON FLOW FIELDS AND DIFFUSION FIELDS WAS CLARIFIED EXACTLY. THE LOCATION OF EXHAUST INLETS HARDLY AFFECTS THE FLOW FIELDS IN ROOM MODELS. HOWEVER, WHEN THE NUMBER OF THE SUPPLY OUTLETS IS DECREASED, THE FLOW UNITS CORRESPONDING TO THE ELIMINATED SUPPLY OUTLETS DISAPPEAR. THE VENTILATION EFFECTIVENESS OF DIFFERENT ARRANGEMENTS OF SUPPLY OUTLETS IS QUANTITATIVELY ANALYSED. THE ARRANGEMENTS OF SUPPLY OUTLETS IN A CHECKERED PATTERN ARE SUPERIOR TO THAT IN LINED PATTERN FROM THE VIEWPOINT OF CONTAMINANT DIFFUSION.
Details
- Original title: [In Japanese. / En japonais.]
- Record ID : 1990-0773
- Languages: Japanese
- Source: Transaction of the Society of Heating, Air-conditioning and Sanitary Engineers of Japan - n. 40
- Publication date: 1989
- Document available for consultation in the library of the IIR headquarters only.
Links
See other articles in this issue (1)
See the source
Indexing
- Themes: Air conditioning in laboratories and industry
- Keywords: Contamination; Calculation; Ventilation; Design; Simulation; Clean room; Air conditioning
-
NUMERICAL AND EXPERIMENTAL STUDY ON TURBULENT D...
- Author(s) : MURAKAMI S., KATO S., SUYAMA Y.
- Date : 1988
- Languages : English
View record
-
STUDY ON AIR VELOCITY DISTRIBUTION IN CONVENTIO...
- Author(s) : MURAKAMI S., KATO S., SUYAMA Y.
- Date : 1988
- Languages : Japanese
- Source: Transaction of the Society of Heating, Air-conditioning and Sanitary Engineers of Japan - n. 37
View record
-
STUDY ON AIR VELOCITY DISTRIBUTION IN CONVENTIO...
- Author(s) : MURAKAMI S., KATO S., SUYAMA Y.
- Date : 1988
- Languages : Japanese
- Source: Transaction of the Society of Heating, Air-conditioning and Sanitary Engineers of Japan - n. 37
View record
-
Contamination risk factor of a damaged clean room.
- Author(s) : ZAMANKHAN P.
- Date : 2013/06/16
- Languages : English
- Source: Clima 2013. 11th REHVA World Congress and 8th International Conference on Indoor Air Quality, Ventilation and Energy Conservation in Buildings.
- Formats : PDF
View record
-
NUMERICAL STUDY ON DIFFUSION FIELD AS AFFECTED ...
- Author(s) : MURAKAMI S., KATO S., SUYAMA Y.
- Date : 1989
- Languages : English
View record