Summary
In order to improve the energy efficiency of computer room air conditioners, this paper proposed an air conditioner with separate type heat pipe and evaporative cooling, taking a computer room of Urumchi as the object, the transient simulation of the system is carried out based on the mathematical model. The annual dynamical performance is compared with the conventional computer room air-conditioning system, which showed that the composite air-conditioning system had better energy efficiency, whose power consumption reduced 37.48%, and COP increased 37.24%; Furthermore, because of the operation of heat pipe mode, the running time of the vapor compression cooling mode and the starting number of the compressor decreased 39.60% and 53.76% respectively, which extended the life of the compressor.
Available documents
Format PDF
Pages: 9 p.
Available
Public price
20 €
Member price*
Free
* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).
Details
- Original title: Study on the computer room air conditioner with separate type heat pipe and evaporative cooling.
- Record ID : 30015763
- Languages: English
- Source: Proceedings of the 24th IIR International Congress of Refrigeration: Yokohama, Japan, August 16-22, 2015.
- Publication date: 2015/08/16
- DOI: http://dx.doi.org/10.18462/iir.icr.2015.0185
Links
See other articles from the proceedings (657)
See the conference proceedings
-
Study on outdoor air-cooling systems for data c...
- Author(s) : UDAGAWA Y., SEKIGUCHI K., YANAGI M., et al.
- Date : 2012/12
- Languages : Japanese
- Source: Transactions of the Society of Heating, Air-Conditioning and Sanitary Engineers of Japan - n. 189
View record
-
Operation analysis on refrigeration system comb...
- Author(s) : HE H., WANG W., QI Z., et al.
- Date : 2016/07/11
- Languages : English
- Source: 2016 Purdue Conferences. 16th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
View record
-
Data center heat rejection: indirect air-side e...
- Author(s) : DUNNAVANT K.
- Date : 2011/03
- Languages : English
- Source: ASHRAE Journal - vol. 53 - n. 3
View record
-
Data center heat rejection: indirect air-side e...
- Author(s) : DUNNAVANT K.
- Date : 2012
- Languages : Japanese
- Source: SHASE - vol. 86 - n. 3
View record
-
Koeltechnologieën voor zeer energieefficiënte d...
- Author(s) : BERENDS E.
- Date : 2012/02
- Languages : Dutch
- Source: Koude & Luchtbehandeling - vol. 105
View record