
IIR document
Subcooling with AC and adiabatic gas cooling for energy efficiency improvement: field tests and modelling of CO2 booster systems.
Number: pap. n. 784
Author(s) : CORTELLA G., COPPOLA M. A., D'AGARO P.
Summary
In the last decade several plant configurations and components have been proposed to increase the efficiency of CO2 refrigeration systems. Among these, subcooling is considered a simple but effective solution, together with the employment of adiabatic cooling systems at the gas cooler. In this work, a fully instrumented CO2 booster plant installed in a supermarket is considered, to compare parallel compression, subcooling and adiabatic cooling. Subcooling is performed taking advantage of chilled water available from the HVAC system. The experimental data are used to validate a model for the comparison on a yearly basis. Parallel compression and subcooling show to be almost equivalent in terms of yearly energy use, while the adiabatic cooling system gives the best performance. Comparisons reveal that the subcooler cooling capacity should be chosen carefully to avoid oversizing, while the influence of the EER for the chiller appears quite small. Subcooling performed at the expense of an HVAC plant shows to be an interesting solution, while a great benefit was experienced with the employment of an adiabatic gas cooler.
Available documents
Format PDF
Pages: 8
Available
Public price
20 €
Member price*
Free
* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).
Details
- Original title: Subcooling with AC and adiabatic gas cooling for energy efficiency improvement: field tests and modelling of CO2 booster systems.
- Record ID : 30026211
- Languages: English
- Source: Proceedings of the 25th IIR International Congress of Refrigeration: Montréal , Canada, August 24-30, 2019.
- Publication date: 2019/08/24
- DOI: http://dx.doi.org/10.18462/iir.icr.2019.0784
Links
See other articles from the proceedings (632)
See the conference proceedings
Indexing
-
Themes:
CO2;
Supermarkets, display cabinets - Keywords: Energy consumption; Commercial building; Display cabinet; R744; Supermarket; Subcooling; Modelling; Testing; Air conditioning; CO2
-
Soluciones para reducir el consumo energético d...
- Author(s) : MATEU-ROYO C., KARAMPOUR M., SAWALHA S., et al.
- Date : 2018/06/19
- Languages : Spanish
- Source: CYTEF 2018. IX Congreso Ibérico y VII Congreso Iberoamericano de Ciencias y Técnicas del Frío, Valencia, España, 19-21 junio 2018.
- Formats : PDF
View record
-
The influence of evaporation pressure dynamics ...
- Author(s) : SCHULTE A., FÖRSTERLING S., LARSEN L., HEERUP C., BACHER P., GOTTSCH R., TEGETHOFF W., ZÜHLSDORF B., KOEHLER J.
- Date : 2023/08/21
- Languages : English
- Source: Proceedings of the 26th IIR International Congress of Refrigeration: Paris , France, August 21-25, 2023.
- Formats : PDF
View record
-
The use of an R718 subcooler in an R744 superma...
- Author(s) : HANSLIK F., SCHULTE A., FRIESE J., HELLMANN S., TEGETHOFF W., KOEHLER J.
- Date : 2023/08/21
- Languages : English
- Source: Proceedings of the 26th IIR International Congress of Refrigeration: Paris , France, August 21-25, 2023.
- Formats : PDF
View record
-
Combined refrigeration, heating and air conditi...
- Author(s) : COPPOLA M. A., CORTELLA G., D'AGARO P.
- Date : 2019/08/24
- Languages : English
- Source: Proceedings of the 25th IIR International Congress of Refrigeration: Montréal , Canada, August 24-30, 2019.
- Formats : PDF
View record
-
Sustainable low carbon heating and cooling for ...
- Author(s) : COLOMBO I., MAIDMENT G. G., CHAER I., et al.
- Date : 2011/07
- Languages : English
- Formats : PDF
View record