IIR document
The applications of shallow layer water-source heat pump and the review in Wuhan.
Author(s) : LI Y.
Summary
According to the survey and test in the design and operation of shallow-layer water-source heat pump system in Wuhan, the authors of this paper obtained the following findings: the efficiency can be increased by 45.65% when the shallow layer water-source heat pump is used to supply cooling, and the energy conservation rate reaches 72.56% when the same type pump being used for heating, but the operational cost of water-source pump system is approximately 18.6 yuan(RMB)/(m2.a), which is by far lower than the mean cost value 51.62 yuan(RMB)/(m2.a) for the energy consumption of central air conditioning in Wuhan. The initial investment in the water-source heat pump system may save the most, and in this article the assessment method is also discussed for the project in employing underground water-source heat pump unit.
Available documents
Format PDF
Pages: ICR07-E2-844
Available
Public price
20 €
Member price*
Free
* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).
Details
- Original title: The applications of shallow layer water-source heat pump and the review in Wuhan.
- Record ID : 2008-0907
- Languages: English
- Source: ICR 2007. Refrigeration Creates the Future. Proceedings of the 22nd IIR International Congress of Refrigeration.
- Publication date: 2007/08/21
Links
See other articles from the proceedings (839)
See the conference proceedings
Indexing
- Themes: Other heat-pump applications
- Keywords: Ground-water; Heat source; Heat pump; Survey; COP; Heating
-
A COMPLETE HEAT PUMP INSTALLATION FOR CENTRAL H...
- Author(s) : DU BOULLAY V.
- Date : 1986/11/05
- Languages : English
View record
-
Sistem toplotne pumpe sa tlom kao izvorom toplo...
- Author(s) : MICHOPOULOS A., BOZIS D., KIKIDIS P., et al.
- Date : 2005/11/02
- Languages : Serbian
- Source: Zbornik radova pisanih za 36. kongres o klimatizaciji, grejanju, hladenju + CD-ROM./ Proceedings of the 36th International HVAC&R congress + CD-ROM.
View record
-
Performance evaluation under the actual operati...
- Author(s) : KIM E., JEONG Y., LEE J., et al.
- Date : 2009/05/20
- Languages : English
- Source: ACRA-2009. The proceedings of the 4th Asian conference on refrigeration and air conditioning: May 20-22, 2009, Taipei, R.O.C.
- Formats : PDF
View record
-
Wärmepumpenheizanlagen mit Erdwärmesonden.
- Author(s) : HESSLINGER S.
- Date : 1999/11/17
- Languages : German
- Source: DKV-Tagungsbericht 26. 1999, Berlin.
View record
-
Research progress and application foreground of...
- Author(s) : WANG Y., LU N. C.
- Date : 2006/05/21
- Languages : English
- Source: ACRA-2006. Proceedings of the 3rd Asian conference on refrigeration and air conditioning.
View record