Summary
Ground-coupled heat pump (GCHP) systems often require antifreeze in the circulating water in locations with significant heating seasons, such as Northern China. In this study, the effects of antifreeze in the circulating water on operation performance of ground heat exchangers (GHEs) was investigated. A theoretical model was derived to analyze the antifreeze effect. Then the model was
validated by an experimental system. Based on the effects of antifreeze solution on heat transfer performance and friction loss, the correction factor of flowrate and friction loss are given. In addition, the design method for GHEs in cold regions are also discussed.
Available documents
Format PDF
Pages: 9
Available
Public price
20 €
Member price*
Free
* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).
Details
- Original title: The effects of antifreeze in the circulating water on the operation performance of ground heat exchangers.
- Record ID : 30026802
- Languages: English
- Source: Proceedings of the 25th IIR International Congress of Refrigeration: Montréal , Canada, August 24-30, 2019.
- Publication date: 2019/08/24
- DOI: http://dx.doi.org/10.18462/iir.icr.2019.1788
Links
See other articles from the proceedings (632)
See the conference proceedings
Indexing
-
Themes:
Thermodynamic measurements;
Evaporators, condensers and other heat exchangers;
Refrigerant circulation: piping, control, automation, safety - Keywords: Friction; China; Heat transfer; Antifreeze; Performance; Ground-source system; Modelling; Expérimentation; Case study; Heat exchanger; Cold climate
-
Alternative positions of internal heat exchange...
- Author(s) : LIU S., WANG J., DAI B., YANG X., NIAN V., LI H., YUAN J.
- Date : 2021/11
- Languages : English
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 131
- Formats : PDF
View record
-
Mélanges frigorigènes : configuration des échan...
- Author(s) : BENSAFI A.
- Date : 2000/03
- Languages : French
- Source: Rev. gén. Froid - vol. 90 - n. 1001
View record
-
Modelling and experimental study for winter per...
- Author(s) : GHOSAL M. K., NAYAK S., TIWARI G. N., et al.
- Date : 2008/01
- Languages : English
- Source: Agric. Eng. Int., CIGR E-J. - vol. 10 - n. EE 07 012
View record
-
Heat transfer analysis of double U-tube ground ...
- Author(s) : KUMAR S., PANDIT J., MURUGESAN K.
- Date : 2019/08/24
- Languages : English
- Source: Proceedings of the 25th IIR International Congress of Refrigeration: Montréal , Canada, August 24-30, 2019.
- Formats : PDF
View record
-
Geothermal earth heat exchanger.
- Author(s) : PANICKER R.
- Date : 2016/11
- Languages : English
- Source: Air Conditioning and Refrigeration Journal - vol. 19 - n. 6
- Formats : PDF
View record