IIR document
The exergy analysis of the open-cycle absorption chiller.
Author(s) : LU S. K., ZHANG X. S., MA J. M.
Summary
The principle and characteristics of the open-cycle absorption chiller are introduced. The model is established for the exergy analysis of the wet air and the solution. In the hypothesis operating mode, the process design and the thermal computation are carried for the system. Then each condition parameter of the system is set. Applying the balanced equation, the exergy destruction of each part of the chiller is derived. The chiller has an exergy efficiency of 18.13%. The analysis shows that the site with the maximum losses of exergy is the regenerator. It is discussed that how to reduce the loss of the exergy in the regenerator and how to increase exergy efficiency for the system.
Available documents
Format PDF
Pages: ICR07-B2-1204
Available
Public price
20 €
Member price*
Free
* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).
Details
- Original title: The exergy analysis of the open-cycle absorption chiller.
- Record ID : 2008-0632
- Languages: English
- Source: ICR 2007. Refrigeration Creates the Future. Proceedings of the 22nd IIR International Congress of Refrigeration.
- Publication date: 2007/08/21
Links
See other articles from the proceedings (839)
See the conference proceedings
-
A miniature heat-actuated air conditioner for d...
- Author(s) : DROST M. K., FRIEDRICH M.
- Date : 1998/06/17
- Languages : English
- Source: Heat pump systems for single-room applications. Workshop proceedings.
View record
-
Development of a pre-industrial prototype of an...
- Author(s) : CASTRO J., OLIET C., OLIVA A., et al.
- Date : 2006/05/29
- Languages : English
- Source: 7th IIR-Gustav Lorentzen Conference on Natural Working Fluids (GL2006). Proceedings
- Formats : PDF
View record
-
Modelling and optimisation of absorption system...
- Author(s) : MOINARD S., GIVOIS E.
- Date : 1997/08
- Languages : English
- Source: CLIMA 2000, Brussels 1997, August 30 to September 2, Congress Palace.
View record
-
La miniaturizzazione degli assorbitori a bromur...
- Author(s) : BRAIDOTTI F.
- Date : 2003/06/27
- Languages : Italian
- Source: Le ultime tecnologie del freddo e del condizionamento [+ annex, videolezione and CD-ROM]./ Technological innovations in refrigeration and air conditioning [+ annex, video and CD-ROM].
View record
-
The characteristic equations of absorption chil...
- Author(s) : HELLMANN H. M., SCHWEIGLER C., ZIEGLER F.
- Date : 1999/03/24
- Languages : English
- Source: Proceedings of the International Sorption Heat Pump Conference.
View record