THE REFRIGERATION STATIONS FOR THE NATURAL GAS PIPELINE URENGOI (USSR)-CENTRAL EUROPE.
[In Italian. / En italien.]
Author(s) : TROLLUX J.
Type of article: Article
Summary
THIS PAPER DESCRIBES THE TECHNICAL FEATURES OF THE REFRIGERATING STATIONS INSTALLED AT THE HEAD OF THE PIPELINE CONVEYING NATURAL GAS FROM SIBERIAN FIELDS TO CENTRAL EUROPE. GAS COOLING TO 269 K (-4 DEG C) IS NECESSARY TO PREVENT THAWING OF THE PERMAFROST AND CONSEQUENT PIPE SUBSIDENCE. THERE ARE SIX STATIONS TO HANDLE A TOTAL FLOW RATE OF 430 MILLION CUBIC METRES PER DAY OF NATURAL GAS. ALL THE STATIONS ARE EQUIPPED WITH BASIC REFRIGERATING SYSTEMS USING PROPANE (R290) AS THE REFRIGERANT AS IT IS EASILY AVAILABLE FROM NEAR BY GAS FIELD FACILITIES. E. F.
Details
- Original title: [In Italian. / En italien.]
- Record ID : 1987-0019
- Languages: Italian
- Source: Industria italiana del Freddo - vol. 38 - n. 6
- Publication date: 1984
- Document available for consultation in the library of the IIR headquarters only.
Links
See the source
Indexing
- Themes: LNG and LPG
- Keywords: Permafrost; Propane; Gas pipeline; Natural gas; Centrifugal compressor
-
Pipeline drying using dehumidified air with low...
- Author(s) : AHMED S. Y., GANDHIDASAN P., FARAYEDHI A. A. al-
- Date : 1998/05
- Languages : English
- Source: Applied Thermal Engineering - vol. 18 - n. 5
View record
-
MOBIL'S PIPE FREEZE BREAKS NEW GROUND.
- Date : 1987
- Languages : English
- Source: Pipes Pipelines int. - vol. 32 - n. 4
View record
-
PROBLEMS AND SOLUTIONS FOR LNG PIPELINE.
- Author(s) : NGUYEN VAN TUYEN, REGNAUD P.
- Date : 1983
- Languages : English
- Source: Oil Gas J. - vol. 81 - n. 4
View record
-
Thermodynamic analysis and optimization of prop...
- Author(s) : SHI Y., GU A., WANG R., et al.
- Date : 2002/04/23
- Languages : English
- Source: Cryogenics 2002. Proceedings of the 7th Cryogenics Conference
- Formats : PDF
View record
-
Trans-Urals replacement NGL line nearing instal...
- Date : 1994/01/24
- Languages : English
- Source: Oil Gas J. - vol. 92 - n. 4
View record