THERMAL INSULATING SANDWICH-STRUCTURES AND A SUBSTITUTE FOR R11.

[In Dutch. / En néerlandais.]

Author(s) : NIJHOF A. H. J.

Type of article: Article

Summary

TO RECEIVE AN ATP-FRC CERTIFICATE FOR REFRIGERATING TRUCKS, IT IS NECESSARY THAT THE HEAT TRANSFER COEFFICIENT OF THE CARGO-SPACE NOT EXCEED 0.4 W/M2. K. IF FOR TRAFFIC OR LOADING REASONS THE SIDE-WALLS MUST BE THIN, A SANDWICH STRUCTURE WITH A CORE OF R11-EXPANDED PUR FOAM IS PREFERABLE, BECAUSE OF LOW HEAT CONDUCTION. BUT WITH AGE, THE THERMAL INSULATION DIMINISHES STEADILY. THE PAPER PRESENTS SOME RESEARCH FOR SOLVING THE PROBLEM.

Details

  • Original title: [In Dutch. / En néerlandais.]
  • Record ID : 1992-1917
  • Languages: Dutch
  • Source: Koude & Luchtbehandeling - vol. 84 - n. 9
  • Publication date: 1991/09
  • Document available for consultation in the library of the IIR headquarters only.