THERMAL TRANSMITTANCE OF CONCRETE BLOCK WALLS WITH CORE INSULATION.
Author(s) : GEMM M. G. van
Summary
THERMAL TRANSMITTANCE VALUES OF CONCRETE BLOCK WALLS, WITH AND WITHOUT CORE INSULATION, TESTED AT THREE LABORATORIES ARE SUMMARIZED. INSULATIONS WERE PERLITE, VERMICULITE, EXPANDED POLYSTYRENE (EPS) BEADS, AND EPS INSERTS. MEASURED VALUES ARE COMPARED TO VALUES CALCULATED USING THE ISOTHERMAL PLANES METHOD. FOR EMPTY CORE CONCRETE BLOCK WALLS WITH KNOWN, CONCRETE THERMAL CONDUCTIVITY, MEASURED VALUESWERE WITHIN 10% OF CALCULATED VALUES. HOWEVER, FOR WALLS WITH CORE INSULATION, MEASURED VALUES DIFFERED BY 0 TO 40% FROM CALCULATED VALUES.
Details
- Original title: THERMAL TRANSMITTANCE OF CONCRETE BLOCK WALLS WITH CORE INSULATION.
- Record ID : 1987-0095
- Languages: English
- Publication date: 1985
- Source: Source: ASHRAE Trans.
vol. 91; n. 2B; 17-35; 7 fig.; 6 tabl.; 21 ref.; append.; discuss. - Document available for consultation in the library of the IIR headquarters only.
Indexing
- Themes: Thermodynamic measurements
- Keywords: Vermiculite; Thermal conductivity; Polystyrene; Insulant; Concrete; Calculation; Measurement; Perlite; Insulation; Air conditioning; K coefficient
-
EFFECT OF MOISTURE ON THE THERMAL CONDUCTIVITY ...
- Author(s) : CAMMERER W. F.
- Date : 1987
- Languages : German
- Source: Bauphysik - vol. 9 - n. 6
View record
-
SOME ASPECTS OF THE THERMAL PERFORMANCE OF INDI...
- Author(s) : MAITI C. R.
- Date : 1982
- Languages : English
- Source: Cryogenics - vol. 22 - n. 10
View record
-
THE EFFECT OF MOISTURE ON THE THERMAL CONDUCTIV...
- Author(s) : STUCKES A. D., TINKER J. A., SIMPSON A.
- Date : 1986
- Languages : English
- Source: Build. Serv. Eng. Res. Technol. - vol. 7 - n. 1
View record
-
K-factors for HVAC ducts: numerical and experim...
- Author(s) : GAN G., RIFFAT S. B.
- Date : 1995
- Languages : English
- Source: Build. Serv. Eng. Res. Technol. - vol. 16 - n. 3
View record
-
THE THERMAL CONDUCTIVITY AND THE OVERALL COEFFI...
- Author(s) : YAMADA E.
- Date : 1982
- Languages : Japanese
- Source: Transaction of the Society of Heating, Air-conditioning and Sanitary Engineers of Japan - n. 19
View record