Thermodynamic analysis of an ejector-flash tank-absorption cooling system.
Author(s) : SIRWAN R., ALGHOUL M. A., SOPIAN K., et al.
Type of article: Article
Summary
The performance of a combined ejector-absorption cooling cycle has the potential for further investigation. Improving the performance of the system can be achieved by adding a flash tank to the combined cycle. In this study, an analysis based on the second law of thermodynamics is used to evaluate the cycle before and after modification. A mathematical model is developed to calculate the entropy generation in each component and the total entropy generation of the system, as well as to evaluate the exergy losses. Under operating conditions that match the ambient conditions and a certain application in Malaysia (T(gen) = 85°C; T(cond) = T(abs) = 30°C; and T(evp) = 0°C), the coefficient of performance (COP) and exergetic efficiency (COP(exep) values before and after modification are (0.844, 0.875) and (0.459, 0.476), respectively. The maximum exergy loss is found in the evaporator in both cycles, followed by the condenser and the absorber. A statistical t-test is carried out to establish the significance of the differences in the COP and the COP(exe) before and after modification. It is found that there is significant improvement in combined cycle performance after modification. Overall, adding the flash tank to the combined cycle can be considered a novel enhancement.
Details
- Original title: Thermodynamic analysis of an ejector-flash tank-absorption cooling system.
- Record ID : 30011099
- Languages: English
- Source: Applied Thermal Engineering - vol. 50 - n. 1
- Publication date: 2013/01
- DOI: http://dx.doi.org/10.1016/j.applthermaleng.2013.03.031
Links
See other articles in this issue (64)
See the source
Indexing
-
Computer modelling and testing of low pressure ...
- Author(s) : SMITH S. J., RIFFAT S. B., WU S., et al.
- Date : 1997/10/05
- Languages : English
- Source: CIBSE National Conference 1997. Proceedings.
View record
-
Performance investigation and precooler design ...
- Author(s) : MA Y., HU P.
- Date : 2024/06
- Languages : English
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 162
- Formats : PDF
View record
-
Study on the performances of an ejector as adia...
- Author(s) : VEREDA C., VENTAS R., LECUONA A., et al.
- Date : 2011/04/06
- Languages : English
- Source: Sources/sinks Alternative to the Outside Air for Heat Pump and Air-conditioning Techniques (Alternative Sources - AS), Padua, Italy, April 5-7, 2011. / International Sorption Heat Pump Conference (ISHPC11), Padua, Italy, April 6-8, 2011.
- Formats : PDF
View record
-
Development and analysis of a novel CSP source ...
- Author(s) : KHALIQ A., REFAEY H. A., ALHARTHI M. A.
- Date : 2021/10
- Languages : English
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 130
- Formats : PDF
View record
-
Thermo-economic optimization of an ORC driven h...
- Author(s) : MOUNIER V., MENDOZA L. C., SCHIFFMANN J.
- Date : 2017/09
- Languages : English
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 81
- Formats : PDF
View record