Thermodynamic Analysis of CO2 Transcritical Booster System for Supermarket Refrigeration in Warm Climatic Conditions.
Author(s) : PUROHIT N., GUPTA D. K., DASGUPTA M. S.
Type of article: Article
Summary
This article presents a thermodynamic analysis of a hypothetical trans-critical CO2 refrigeration system with enhanced booster and parallel compression for supermarket application in warm climatic conditions (35-50°C). The proposed system simultaneously incorporates two medium temperature and three low temperature loads for five different cooling demands typically found in supermarket application. These are HVAC load at 5°C, storage of dairy products at O°C, frozen ice cream, vegetable and animal products at -10°C, -20°C and -30°C respectively. Some of the major parameters affecting performance like gas cooler operating pressure, inter-mediate vessel pressure, mass flow rate and gas cooler inlet temperature are investigated to reveal the practicality of the proposed system. The simulation results show that the new cycle configuration has a distinct advantage over a few other modified cycles proposed from time to time for supermarket refrigeration in warm climatic conditions. A few potential improvement strategies of COP are also discussed.
Details
- Original title: Thermodynamic Analysis of CO2 Transcritical Booster System for Supermarket Refrigeration in Warm Climatic Conditions.
- Record ID : 30024608
- Languages: English
- Source: Air Conditioning and Refrigeration Journal - vol. 20 - n. 4
- Publication date: 2017/10
Links
See other articles in this issue (4)
See the source
Indexing
-
Themes:
CO2;
Supermarkets, display cabinets - Keywords: Comparison; R744; Supermarket; Simulation; Transcritical cycle; Thermodynamic cycle; Compression; CO2; Hot climate
-
Thermodynamic analysis of CO2 trans-critical bo...
- Author(s) : PUROHIT N., GUPTA D. K., DASGUPTA M. S.
- Date : 2016/04/07
- Languages : English
- Source: 4th IIR International Conference on Sustainability and the Cold Chain. Proceedings: Auckland, New Zealand, April 7-9, 2016.
- Formats : PDF
View record
-
Supermarket application. Effects of sub-cooling...
- Author(s) : MAZZOLA D., SHEEHAN J., BORTOLUZZI D., et al.
- Date : 2016/08/21
- Languages : English
- Source: 12th IIR Gustav Lorentzen Conference on Natural Refrigerants (GL2016). Proceedings. Édimbourg, United Kingdom, August 21st-24th 2016.
- Formats : PDF
View record
-
Environment-friendly refrigeration packs for In...
- Author(s) : BLUST S., SINGH S., HAFNER A., et al.
- Date : 2018/06/18
- Languages : English
- Source: 13th IIR Gustav Lorentzen Conference on Natural Refrigerants (GL2018). Proceedings. Valencia, Spain, June 18-20th 2018.
- Formats : PDF
View record
-
Simulation and optimization of a R744 two- temp...
- Author(s) : HUANG Z., ZHAO H., YU Z., et al.
- Date : 2018/06
- Languages : English
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 90
- Formats : PDF
View record
-
Current limits of CO2 compressors wo...
- Author(s) : NEBOT-ANDRÉS L., SÁNCHEZ D., CABELLO R., CALLEJA-ANTA D., FOSSI C., LLOPIS R.
- Date : 2021/09
- Languages : English
- Source: 12th International Conference on Compressors and their Systems
- Formats : PDF
View record