Transient pool boiling from downward-facing curved surfaces.

Author(s) : GENK M. el-, GLEBOV A. G.

Type of article: Article

Summary

When compared to that of a flat surface section of the same material and dimensions, the average pool boiling curve for the 12.8 mm thick section showed significant increases in the maximum heat flux (from 0.21 to 0.41 megawatts/m2) and the minimum film boiling heat flux (from 2 to 13 kilowatts/m2) and about 11.5 and 60 K increase in the corresponding wall superheats, respectively.

Details

  • Original title: Transient pool boiling from downward-facing curved surfaces.
  • Record ID : 1996-1498
  • Languages: English
  • Source: International Journal of Heat and Mass Transfer - vol. 38 - n. 12
  • Publication date: 1995/08

Links


See other articles in this issue (3)