Two stage refrigeration circuit simulation.

Author(s) : SMITH M. G., LEPPER S. P.

Summary

Typical automotive air conditioning refrigeration systems employ thermostatic expansion valve or orifice tube controls in a single stage refrigerant circuit. A new automotive air conditioning compressor has been developed that has a two stage compression process. This compressor can function in a single stage circuit or in a two stage circuit. For a two stage circuit, the results show that the compressor speed and input power can be reduced by 19%, while providing the same cooling capacity.

Details

  • Original title: Two stage refrigeration circuit simulation.
  • Record ID : 1999-3833
  • Languages: English
  • Source: Proceedings of the 1998 Purdue International Refrigeration Conference.
  • Publication date: 1998/07/14
  • Document available for consultation in the library of the IIR headquarters only.

Links


See other articles from the proceedings (67)