Uncertainty quantification of experimental air conditioner performance due to the uncertainty of the equation of state.
Number: pap. 2539
Author(s) : CHEUNG H., FRUTIGER J., BELL I. H., et al.
Summary
In previous literature, the uncertainty analyses of experimental performance metrics of air conditioners usually ignored the uncertainty due to the equation of state (EoS) of the refrigerants. One possible reason was that the uncertainty reported in the EoS literature was much smaller than the one of the system performance measurement. However, with the advancement of measurement technologies, the impact of measurement uncertainty on the air conditioner performance calculation is lowered and becomes on par with that of the EoS. Simultaneously, new research findings give more comprehensive understanding of the EoS uncertainties, such that the uncertainty of EoS reported in previous studies was underestimated under some conditions. To examine if the uncertainty of experimental results of a thermal system are significantly affected by the new findings, an uncertainty analysis is carried out with experimental data of an air conditioner using propane. The results show that the uncertainty of the EoS has a more significant impact on experimental results involving saturation temperature such as subcooling and superheat measurement than the uncertainties of the measurement, while its impact on the uncertainty of the measured heat transfer rate is still not as significant in most cases.
Available documents
Format PDF
Pages: 10
Available
Public price
20 €
Member price*
15 €
* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).
Details
- Original title: Uncertainty quantification of experimental air conditioner performance due to the uncertainty of the equation of state.
- Record ID : 30024639
- Languages: English
- Source: 2018 Purdue Conferences. 17th International Refrigeration and Air-Conditioning Conference at Purdue.
- Publication date: 2018/07/09
Links
See other articles from the proceedings (252)
See the conference proceedings
Indexing
- Themes: Other air-conditioning equipment
- Keywords: Air conditioner; R290; Propane; Performance; Expérimentation; Equation of state; Refrigerant
-
The first 60,000 HC-290 split air conditioners ...
- Author(s) : RAJADHYAKSHA D., WADIA B. J., COLBOURNE D.
- Date : 2014/08/02
- Languages : English
- Source: 11th IIR Gustav Lorentzen Conference on Natural Refrigerants (GL2014). Proceedings. Hangzhou, China, August 31-September 2, 2014.
- Formats : PDF
View record
-
Performance assessment of air conditioners with...
- Author(s) : PADALKAR A. S., MALI K. V., RAJADHYAKSHA D. D., et al.
- Date : 2010/04/12
- Languages : English
- Source: 9th IIR-Gustav Lorentzen Conference on Natural Working Fluids (GL2010). Proceedings. Sydney, Australia, April 12-14, 2010.
- Formats : PDF
View record
-
Development of a propane double duct room air c...
- Author(s) : RIGHETTI G., CAMPIDELLI M., BOTTARO M., et al.
- Date : 2019/08/24
- Languages : English
- Source: Proceedings of the 25th IIR International Congress of Refrigeration: Montréal , Canada, August 24-30, 2019.
- Formats : PDF
View record
-
R290 leakage mass flow rate from a refrigeratin...
- Author(s) : COLBOURNE D., LIU Z. X.
- Date : 2012/06/25
- Languages : English
- Source: 10th IIR-Gustav Lorentzen Conference on Natural Working Fluids (GL2012). Proceedings. Delft, The Netherlands, June 25-27, 2012.
- Formats : PDF
View record
-
Minimum airflow rates to dilute R290 concentrat...
- Author(s) : COLBOURNE D., SUEN K. O.
- Date : 2018/06/18
- Languages : English
- Source: 13th IIR Gustav Lorentzen Conference on Natural Refrigerants (GL2018). Proceedings. Valencia, Spain, June 18-20th 2018.
- Formats : PDF
View record