Use of propane (R290) for a centralized unitary air conditioning package.
Utilisation du propane (R290) pour un ensemble de climatisation monobloc centralisé.
Author(s) : TREADWELL D. W.
Type of article: Article
Summary
The article aims at giving the results of the application of propane in a centralized air conditioning unit, replacing R22. It also discusses advantages and disadvantages of propane utilization. The propane properties ressemble to those of R22. The utilization of propane has firstly been investigated by testing a centralized air conditioning unit of 8 kilowatts. Then, the compressor has been replaced by an equivalent-efficiency compressor with an 18% increased displacement; and the unit has been charged with propane. This paper is a translation of an article of the "International CFC and Halon alternatives Conference, Baltimore December 1991", mentionned in the Bulletin (abstract n. 92-0518).
Details
- Original title: Utilisation du propane (R290) pour un ensemble de climatisation monobloc centralisé.
- Record ID : 1993-0148
- Languages: French
- Source: Rev. gén. Froid - vol. 82 - n. 5
- Publication date: 1992/06
- Document available for consultation in the library of the IIR headquarters only.
Links
- See translations: APPLICATION OF PROPANE (R290) TO A SINGLE PACKAGED UNITARY AIR-CONDITIONING PRODUCT.
See other articles in this issue (4)
See the source
Indexing
-
Themes:
CFCs;
Other air-conditioning equipment;
Hydrocarbons - Keywords: Refrigerating circuit; CFC; Air conditioner; Substitute; Propane; Performance
-
Experiment on R290 substituting for R22 in a ro...
- Author(s) : LI T., YANG J., ZENG Z., et al.
- Date : 2010/08
- Languages : Chinese
- Source: Journal of Refrigeration - vol. 31 - n. 4
- Formats : PDF
View record
-
Experimental study of split room air conditione...
- Author(s) : YANG L., WU J., HOU J.
- Date : 2013/04
- Languages : Chinese
- Source: Journal of Refrigeration - vol. 34 - n. 2
- Formats : PDF
View record
-
Evaluación de las prestaciones de acondicionado...
- Author(s) : PADALKAR A. S., MALI K. V., RAJADHYAKSHA D. D., et al.
- Date : 2011/03
- Languages : Spanish
- Source: IIF-IIR/Frío Calor Aire acond. - vol. 39 - n. 434
- Formats : PDF
View record
-
Valutazione delle prestazioni dei condizionator...
- Author(s) : PADALKAR A. S., MALI K. V., RAJADHYAKSHA D. D., et al.
- Date : 2010
- Languages : Italian
- Source: Industria & Formazione - vol. 34 - n. 344
- Formats : PDF
View record
-
Capillary tube selection for HCFC-22 alternatives.
- Author(s) : JUNG D., PARK C., PARK B.
- Date : 1999/12
- Languages : English
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 22 - n. 8
- Formats : PDF
View record