Using CO2 heat pumps in the heating systems of existing residential buildings: a promising prototype?

CO2-Wärmepumpe für Heizungssysteme in bestehenden Wohngebäuden: ein vielversprechender Prototyp?

Author(s) : HOPPE U.

Type of article: Article

Summary

This article presents the results of a study carried out on an air-to-water heat pump to be used in a residential building. The heat pump's capacity ranges from 11 to 18.9 kW, for outdoor air temperatures ranging from -7 to 7 °C respectively, with the COP varying from 1.7 to 2.62. The aim is to obtain high water temperatures, from 52 to 76°C depending on the outdoor temperature.

Details

  • Original title: CO2-Wärmepumpe für Heizungssysteme in bestehenden Wohngebäuden: ein vielversprechender Prototyp?
  • Record ID : 2004-0887
  • Languages: German
  • Source: Kälte + Klimatechnik (Die) - vol. 56 - n. 10
  • Publication date: 2003/10
  • Document available for consultation in the library of the IIR headquarters only.

Links


See other articles in this issue (7)
See the source