VOID FRACTION MEASUREMENT IN SUBCOOLED FORCED CONVECTIVE BOILING WITH R12.

Author(s) : STANGL G., MAYINGER F.

Type of article: Article

Summary

THE DATA WERE TAKEN AT DIFFERENT HEAT FLUXES IN A 12-TO 25-BAR PRESSURE RANGE, THE MASS FLUXES HAVE BEEN VARIED FROM 500 TO 3,000 KG/M2. S WITH AN INLET SUBCOOLING IN THE RANGE FROM 10 TO 50 K. THE EXPERIMENTS HAVE BEEN CONDUCTED IN AN ANNULAR TEST CHANNEL. THE EXPERIMENTAL RESULTS REVEAL THAT THE VOID FRACTION IS NEARLY CONSTANT FROM THE ONSET OF NUCLEATION BOILING TO A SUBCOOLING OF ABOUT 10 K.

Details

  • Original title: VOID FRACTION MEASUREMENT IN SUBCOOLED FORCED CONVECTIVE BOILING WITH R12.
  • Record ID : 1991-2489
  • Languages: English
  • Source: Exp. Heat Transf. - vol. 3 - n. 3
  • Publication date: 1990
  • Document available for consultation in the library of the IIR headquarters only.

Links


See other articles in this issue (2)
See the source