Analysis of suitable methodologies for compressor mass flow rate correction to other superheat levels and refrigerants.

Analysis of suitable methodologies for compressor mass flow rate correction to other superheat levels and refrigerants.

Summary

This paper investigates the impact of suction conditions and refrigerant on scroll compressor mass flow rate by using calorimeter tests from AHRI-11 and AHRI-21 reports, published by AHRI's Low-GWP Alternative Refrigerants Evaluation program. Two Copeland scroll compressors (20 and 51 cm3) have been analyzed including different suction conditions (SH = 11K, SH = 22K, Ti = 18ºC) and several refrigerants (R134a, R32, R410A, R404A, etc.). Previous studies have explored response surfaces for energy consumption and mass flow rate variables. This study aims to expand the analysis by identifying the optimal approach to extrapolate mass flow rate from specific suction conditions to others SH or suction temperature levels and refrigerants. The current compressor characterization standard relies on the 1981 Dabiri correlation to correct compressor mass flow rate with suction conditions. Thus, this study aims to assess the adequacy of this correction and explore alternative correction methods for improved results.

Available documents

Format PDF

Pages: 6 p.

Available

  • Public price

    20 €

  • Member price*

    15 €

* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).

Details

  • Original title: Analysis of suitable methodologies for compressor mass flow rate correction to other superheat levels and refrigerants.
  • Record ID : 30033383
  • Languages: English
  • Subject: General information
  • Source: 12th CYTEF Congress - Ibero-American Congress of Refrigeration Science and Technology.
  • Publication date: 2024/06/26
  • DOI: http://dx.doi.org/10.21134/a92j4393

Links


See other articles from the proceedings (82)
See the conference proceedings