Analysis of three-fluid separate type heat pipe exchanger.

Author(s) : SHI C., XIN M., CHEN Y.

Type of article: Article

Summary

A universal basic temperature transfer matrix equation is obtained from the analysis of heat transfer. The equation is suitable for predicting performance of the parallel-or counterflow type exchanger in that heat is transferred between one hot fluid and two cold fluids or between two hot fluids and one cold fluid. Finally, a calculated engineering example is taken, and the proposed model and result is proved to be reasonable.