Summary
A typical commercial/institutional building is modelled using a computer program developed by ASHRAE as research project number RP-590. The RP-590 program output was used as input in a separate program written to calculate the CO2 concentration levels in the various zones of this typical building on an hourly basis for a one year cycle. This data allow one to see how VAV A/C systems affect the CO2 levels in each zone as the VAV boxes modulate in response to the thermal load. The CO2 concentration has been suggested to be a good indicator of indoor air quality (IAQ) in typical commercial and institutional settings. IAQ is a hot legal liability issue in the building industry. The results show that a VAV A/C system, that is adequate in all other respects, can adversely affect the indoor air quality of the building. Factors responsible for this are discussed and recommendations and limitations are given for the utilization of this work.
Details
- Original title: Analytical prediction of carbon dioxide concentrations in variable air volume systems.
- Record ID : 2008-2616
- Languages: English
- Source: Clima 2007. WellBeing Indoors. Proceedings of the 9th REHVA World Congress [CD-ROM + Abstract book].
- Publication date: 2007/06/10
Links
See other articles from the proceedings (76)
See the conference proceedings
Indexing
-
Themes:
Other air-conditioning equipment;
Indoor air quality - Keywords: Variable volume; Software; Calculation; Ventilation; Air quality; Air; Air conditioning; Concentration; CO2
-
Measuring air exchanges rates using continuous ...
- Author(s) : YOU Y., BAI Z., JIA C., et al.
- Date : 2007/06/10
- Languages : English
- Source: Clima 2007. WellBeing Indoors. Proceedings of the 9th REHVA World Congress [CD-ROM + Abstract book].
View record
-
VAV SYSTEMS WITH AIR QUALITY CONTROL.
- Author(s) : NORELL L., STRINDEHAG O., PERSSON P. G.
- Date : 1989/08/01
- Languages : English
View record
-
Impianti a portata variabile per il controllo d...
- Author(s) : PEDRANZINI F., JOPPOLO C. M., PASINI A.
- Date : 2002/03/07
- Languages : Italian
- Source: Qualità ambientale e soluzioni sostenibili. 43e Convegno Internazionale AICARR [CD-ROM]./ Environmental quality and sustainable technology. 43rd International conference of AICARR [CD-ROM].
View record
-
VAV system and IAQ control.
- Author(s) : RONG S., RUI D.
- Date : 2000/10/24
- Languages : English
- Source: International Symposium on Air Conditioning in High-Rise Buildings - 2000.
- Formats : PDF
View record
-
Airflow sensing: toward providing indoor air qu...
- Author(s) : SAUER H. J., GEORGE R., UTTERSON E. G.
- Date : 1996/10
- Languages : English
View record