Applications of ejector-heat exchanger in the industrial air cooling installations.
[In Ukrainian. / En ukrainien.]
Author(s) : KOGUT V., BUTOVSKYI I., ZHIKAREVA N., et al.
Type of article: Article
Summary
The paper presents air cooling method in extreme conditions and fine-tuning to the desired parameters. Treatment processes in central air-conditioner with ejector heat exchanger closers in warm and cold periods of the year are shown. In modern industry, it is necessary to maintain a comfortable temperature of air in the workplace. There are many different methods of maintaining the temperature of the air (forced-air ventilation, air conditioning and refrigeration). However, all these methods are poorly effective in hot shops. The solution of this problem is possible with the use of installation with ejector-heat exchanger. Cooling air is carried out by injection of fine water droplets in the air stream overclocked ejector-heat exchanger. The developed device can be used for cooling the workplace in metallurgical production and cooling the internal volume of military equipment in the hot season. Air-conditioning system with ejector heat exchangers allows maintaining in separate rooms set parameters of air through the heat treatment of air, except for the air conditioner, and even in closers distributors.
Details
- Original title: [In Ukrainian. / En ukrainien.]
- Record ID : 30020665
- Languages: Ukrainian
- Source: Holodil'na Tehnika i TehnologiĆ¢ - vol.51 - n.1
- Publication date: 2015/01
- DOI: http://dx.doi.org/10.15673/0453-8307.1/2015.28466
Links
See other articles in this issue (2)
See the source
-
Application of scaling-endoreversible thermodyn...
- Author(s) : YANG H., YANG C.
- Date : 2020/04
- Languages : English
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 112
- Formats : PDF
View record
-
Back to basics: defrost.
- Date : 2008
- Languages : English
- Source: Cold Front - vol. 8 - n. 4
View record
-
Data center heat rejection: indirect air-side e...
- Author(s) : DUNNAVANT K.
- Date : 2011/03
- Languages : English
- Source: ASHRAE Journal - vol. 53 - n. 3
View record
-
Data center heat rejection: indirect air-side e...
- Author(s) : DUNNAVANT K.
- Date : 2012
- Languages : Japanese
- Source: SHASE - vol. 86 - n. 3
View record
-
Energy efficiency analysis between air cooling ...
- Author(s) : WANG Q., PENG S., DING Q.
- Date : 2014/07
- Languages : Chinese
- Source: HV & AC - vol. 44 - n. 292
- Formats : PDF
View record