Approximate estimating method for amplitude damping of atmospheric temperature and effect of heat insulator depth in tunnel with adiabatic icicle prevention work.
Author(s) : OKADA K.
Type of article: Article
Summary
The author developed icicle prevention in railway tunnels by adiabatic treatment of the lining surface. A method of optimizing materials and thickness of the heat insulator is proposed, along with some design conditions such as the width of the heat insulator, the effect of earth covering and snow deposits and the influence of margin length of the heat insulator, based on thermal analysis of a one-or two-dimensional nonsteady-state heat convection-conduction tunnel-ground model.
Details
- Original title: Approximate estimating method for amplitude damping of atmospheric temperature and effect of heat insulator depth in tunnel with adiabatic icicle prevention work.
- Record ID : 1993-3669
- Languages: English
- Source: Q. Rep. RTRI - vol. 33 - n. 4
- Publication date: 1992/11
- Document available for consultation in the library of the IIR headquarters only.
Links
See other articles in this issue (1)
See the source
Indexing
- Themes: Civil engineering
- Keywords: Protection; Ice; Damping; Civil engineering; Tunnel; Rail transport; Antifreeze
-
Effect of frost on railway tracks.
- Author(s) : FACCHIN E.
- Date : 1992/12
- Languages : Italian
- Source: Tec. prof. - vol. 57 - n. 12
View record
-
Guard against freezing in water lines.
- Author(s) : KENNY T. M.
- Date : 1991
- Languages : English
- Source: Chem. Eng. Prog. - vol. 87 - n. 9
View record
-
Actual states and analysis of frost penetration...
- Author(s) : OKADA K.
- Date : 1992/05
- Languages : English
- Source: Q. Rep. RTRI - vol. 33 - n. 2
View record
-
OPTIMUM HEAT INSULATOR FOR ADIABATIC ICICLE PRE...
- Author(s) : OKADA K.
- Date : 1989/02
- Languages : English
- Source: Q. Rep. RTRI - vol. 30 - n. 1
View record
-
THE HUGUENOT TUNNEL: A MAJOR FEAT OF ENGINEERING.
- Author(s) : LOTERYMAN M. J.
- Date : 1988/07
- Languages : English
- Source: S. A. Refrig. Aircond. - vol. 4 - n. 4
View record