Summary
The coefficient of performance (COP) of chiller systems drops when their operating statuses change frequently and deviate from the conventional pair-up operation of chillers, pumps and cooling towers. This paper analyses the chance of having transitional and unconventional operating statuses when the operating variables vary. 12,541 sets of operating conditions were collected from a chiller system at 15 min intervals over 8 months. 1901 sets of transitional statuses and 1565 sets of unconventional statuses were identified. Cox regression models were developed to analyze the impacts of ambient variables, flow- and temperature-related operating variables on transitional statuses. The temperatures of water entering and leaving the condensers were significant variables influencing the chance of switching on/off an extra cooling tower. Survival curves suggested the throttling range of significant variables to identify the chance of transitional statuses causing a COP fluctuation. Minimizing unnecessary transitional and unconventional statuses increased the average system COP by 2.72%.
Available documents
Format PDF
Pages: 182-193
Available
Public price
20 €
Member price*
Free
* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).
Details
- Original title: Assessing operating statuses for chiller system with Cox regression.
- Record ID : 30025378
- Languages: English
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 98
- Publication date: 2019/02
- DOI: http://dx.doi.org/10.1016/j.ijrefrig.2018.10.028
Links
See other articles in this issue (51)
See the source
Indexing
- Themes: Chillers
- Keywords: Cooling tower; Temperature; Chiller; Modelling; COP; Condenser; Water
-
Neural model for forecasting temperature in a d...
- Author(s) : MALINOWSKI P., SULOWICZ M., BUJAK J.
- Date : 2011/06
- Languages : English
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 34 - n. 4
- Formats : PDF
View record
-
Wet bulb temperature: the misunderstood element.
- Author(s) : BURGER R.
- Date : 1993/09
- Languages : English
- Source: Heat. Pip. Air Cond. - vol. 65 - n. 9
View record
-
WATER COOLING PLANT USING NATURAL COLD.
- Author(s) : BARULIN N. Ja., MONAHOV V. S., FILIPKOV A. A.
- Date : 1985
- Languages : Russian
- Source: Kholodilnaya Tekhnika - n. 11
View record
-
Control strategy of chiller plant with precooli...
- Author(s) : JIANG X., GUAN Z., LI M.
- Date : 2012/03
- Languages : Chinese
- Source: Refrigeration - vol. 31 - n. 1
View record
-
Synthesis of cooling water systems with multipl...
- Author(s) : RUBIO-CASTRO E., SERNA-GONZÁLEZ M., PONCE-ORTEGA J. M., et al.
- Date : 2013/01
- Languages : English
- Source: Applied Thermal Engineering - vol. 50 - n. 1
View record