Summary

THE SERVICE LIFE OF A REFRIGERATING MACHINE IS LARGELY DEPENDENT UPON ITS HERMETIC COMPRESSOR. A PARAMETER IS THE RELATIVE SERVICE LIFE THAT IS DEFINED AS THE QUOTIENT OF THE ALLOWABLE INCREASE IN THE RADIAL PLAY IN A BEARING FIT AND THE MEDIUM INCREASE IN THE RADIAL PLAY IN THE SAME FIT AFTER 1,000 SERVICE HOURS OF THE COMPRESSOR. THE METHOD PRESENTED ALLOWS THE CALCULATION OF THE RELATIVE SERVICE LIFE OF A HERMETIC COMPRESSOR BASED UPON SALIENT EXPERIMENTAL DATA.