Central air conditioning based on adsorption and solar energy.
Author(s) : LEITE A. P. F., BELO F. A., MARTINS M. M., et al.
Type of article: Article
Summary
This paper presents the characterization and the pre-dimensioning of an adsorption chiller as part of a 20 kW air conditioning central unit for cooling a set of rooms that comprises an area of 110 m2. The system is basically made up of a cold water storage tank supplied by an activated carbon–methanol adsorption chiller, a hot water storage tank, fed by solar energy and natural gas, and a fan-coil. During an acclimatization of 8 h (9–17 h), the following parameters were obtained for dimensioning the cooling system: 504 kg of activated carbon, 180 L of methanol, 7000 L of hot water, 10,300 L of cold water with its temperature varying in the fan-coil from 1 to 14°C. Considering the mean value of the total daily irradiation in João Pessoa (7°8'S, 34°50'WG), and a cover of regenerating heat supplied by solar energy equivalent to 70%, the adsorption chiller’s expected coefficient of performance (COP) was found to be around 0.6. [Reprinted with permission from Elsevier. Copyright, 2010].
Details
- Original title: Central air conditioning based on adsorption and solar energy.
- Record ID : 30003348
- Languages: English
- Source: Applied Thermal Engineering - vol. 31 - n. 1
- Publication date: 2011/01
- DOI: http://dx.doi.org/10.1016/j.applthermaleng.2010.08.010
Links
See other articles in this issue (3)
See the source
Indexing
-
Themes:
Chillers;
Absorption and adsorption systems;
Solar refrigeration - Keywords: Design; Chiller; Adsorption system; Solar energy; COP; Air conditioning
-
Performance prediction of a two-bed solar adsor...
- Author(s) : UL QADIR N., SAID S. A. M., BEN-MANSOUR R.
- Date : 2018/01
- Languages : English
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 85
- Formats : PDF
View record
-
Study on composite adsorbent for solar adsorpti...
- Author(s) : JIANG Y., WANG G., WU F., et al.
- Date : 2004
- Languages : Chinese
- Source: Journal of Refrigeration - n. 3
- Formats : PDF
View record
-
Experimental analysis of an adsorption air cond...
- Author(s) : LU Z., WANG R., XIA Z.
- Date : 2013/01
- Languages : English
- Source: Applied Thermal Engineering - vol. 50 - n. 1
View record
-
Recent developments of sorption chillers in Eur...
- Author(s) : JAKOB U., KOHLENBACH P.
- Date : 2010/10
- Languages : English
- Source: IIF, Note Inf./IIR, Inf. Note/Bull. IIF-IIR/www.iifiir.org - vol. 90 - n. 2010-5
- Formats : PDF
View record
-
Desarrollos recientes de enfriadores de sorción...
- Author(s) : JAKOB U., KOHLENBACH P.
- Date : 2011/10
- Languages : Spanish
- Source: Frío Calor Aire acondicionado - vol. 39 - n. 440
- Formats : PDF