CENTRIFUGAL PUMP FOR SUPERFLUID HELIUM.

Author(s) : STEWARD W. G.

Type of article: Article

Summary

IN NORMAL HELIUM THE SECOND SET OF DATA SHOWS A LARGE PERFORMANCE IMPROVEMENT OVER THE FIRST SET AS A RESULT OF CHANGES IN MEASUREMENT METHODS AND IN THE PUMP ITSELF. PEAK PUMP EFFICIENCIES OF 46% WERE MEASURED. THE PUMP APPEARED TO PERFORM APPROXIMATELY THE SAME IN HELIUM II AS IN HELIUM I ; HOWEVER, THE HELIUM II DATA ARE NOT ADEQUATE FOR SYSTEM DESIGN OR ANALYSES.

Details

  • Original title: CENTRIFUGAL PUMP FOR SUPERFLUID HELIUM.
  • Record ID : 1986-2165
  • Languages: English
  • Source: Cryogenics - vol. 26 - n. 2
  • Publication date: 1986