Comparative research on air conditioner with gas-injected rotary compressor through injection port on blade.

Number: pap.1369

Author(s) : LIU X., WANG B., SHI W.

Summary

Economizer technology has become a critical method to improve the performance of air conditioners with rotary compressor in low ambient temperature. A novel vapor injection structure on the blade of the rotary compressor has been proposed in previous research to overcome the drawback of the traditional cylinder injection structure. Based on a verified numerical system model, the performance of an air conditioner adopting different economized rotary compressors has been investigated. The results indicate that: compared to the single cylinder rotary compressor with traditional injection structure, the rotary compressor with blade injection structure can enhance the heating capacity and COP by 12.9%~15.7% and 1.5%~4.1% in low ambient temperature, respectively. And compared to the twin-cylinder rotary compressor, the rotary compressor with blade injection structure has a competitive performance.

Available documents

Format PDF

Pages: 6 p.

Available

  • Public price

    20 €

  • Member price*

    15 €

* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).

Details

  • Original title: Comparative research on air conditioner with gas-injected rotary compressor through injection port on blade.
  • Record ID : 30019578
  • Languages: English
  • Source: 2016 Purdue Conferences. 23rd International Compressor Engineering Conference at Purdue.
  • Publication date: 2016/07/11

Links


See other articles from the proceedings (122)
See the conference proceedings