Summary
With the current movement towards net zero energy buildings, many technologies are promoted with emphasis on their superior energy efficiency. The variable refrigerant flow (VRF) and ground source heat pump (GSHP) systems are probably the most competitive technologies among these. However, there are few studies reporting the energy efficiency of VRF systems compared with GSHP systems. In this article, a preliminary comparison of energy efficiency between the air-source VRF and GSHP systems is presented. The computer simulation results show that GSHP system is more energy efficient than the air-source VRF system for conditioning a small office building in two selected US climates. In general, GSHP system is more energy efficient than the air-source VRV system, especially when the building has significant heating loads. For buildings with less heating loads, the GSHP system could still perform better than the air-source VRF system in terms of energy efficiency, but the resulting energy savings may be marginal.
Details
- Original title: Comparison of energy efficiency between variable refrigerant flow systems and ground source heat pump systems.
- Record ID : 2011-0324
- Languages: English
- Source: Energy Build. - vol. 42 - n. 5
- Publication date: 2010/05
- DOI: http://dx.doi.org/10.1016/j.enbuild.2009.10.028
Links
See the source
-
Economy case study of VRV ground source heat pu...
- Author(s) : DONG L., YANG J., ZHANG X.
- Date : 2011/08
- Languages : Chinese
- Source: Journal of Refrigeration - n. 140
- Formats : PDF
View record
-
Optimizing energy consumption of a water-loop v...
- Author(s) : YUAN S., GRABON M.
- Date : 2011/04
- Languages : English
- Source: Applied Thermal Engineering - vol. 31 - n. 5
View record
-
Model-free control and automatic staging of var...
- Author(s) : DONG L., LI Y., SALSBURY T. I., et al.
- Date : 2018/07/09
- Languages : English
- Source: 2018 Purdue Conferences. 17th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
View record
-
The implications of the measured performance of...
- Author(s) : HENDERSON H. I., KHATTAR M. K., CARLSON S. W., et al.
- Date : 2000/06/24
- Languages : English
- Source: ASHRAE Transactions. 2000 ASHRAE Annual Meeting, Minneapolis, Minnesota + CD-ROM.
View record
-
Energy efficiency in a ground source heat pump ...
- Author(s) : DEL COL D., BENASSI G., MANTOVAN M., et al.
- Date : 2012/07/16
- Languages : English
- Source: 2012 Purdue Conferences. 14th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
View record