Comparison of heating and cooling energy consumption by HVAC system with mixing and displacement air distribution for a restaurant dining area in different climates.
Author(s) : ZHIVOV A. M., RYMKEVICH A. A.
Summary
Different ventilation strategies to improve indoor air quality and to reduce HVAC system operating costs in a restaurant with non-smoking and smoking areas and a bar are discussed in this paper. A generic sitting-type restaurant is used for the analysis. Prototype designs for the restaurant chain with more than 200 restaurants in different US climates were analyzed to collect the information on building envelop, dining area size, heat and contaminant sources and loads, occupancy rates, and current design practices.
Details
- Original title: Comparison of heating and cooling energy consumption by HVAC system with mixing and displacement air distribution for a restaurant dining area in different climates.
- Record ID : 1999-3825
- Languages: English
- Source: ASHRAE Transactions. 1998 annual Meeting, Toronto, Ontario + CD-ROM.
- Publication date: 1998
- Document available for consultation in the library of the IIR headquarters only.
Links
See other articles from the proceedings (39)
See the conference proceedings
Indexing
- Themes: Comfort air conditioning
- Keywords: Restaurant; Energy consumption; Comparison; Air displacement; Air conditioning; Climate
-
Comparison of energy consumption between displa...
- Author(s) : HU S., CHEN Q., GLICKSMAN L. R.
- Date : 1999
- Languages : English
- Source: ASHRAE Transactions. 1999 Annual Meeting, Seattle, Washington + CD-ROM.
View record
-
Displacement ventilation in warm climates.
- Author(s) : SKISTAD H.
- Date : 2002/03/07
- Languages : English
- Source: Qualità ambientale e soluzioni sostenibili. 43e Convegno Internazionale AICARR [CD-ROM]./ Environmental quality and sustainable technology. 43rd International conference of AICARR [CD-ROM].
View record
-
A note on the thermal comfort in displacement v...
- Author(s) : MATTSSON M.
- Date : 2000/07/09
- Languages : English
- Source: Air distribution in rooms: ventilation for health and sustainable environment. Roomvent 2000. Proceedings of the 7th international conference.
View record
-
ACV de un edificio de uso universitario.
- Author(s) : IZARD ANAYA E., REY MARTÍNEZ F. J., PALOMAR CARNICERO J. M., et al.
- Date : 2012/02/22
- Languages : Spanish
- Source: CYTEF 2012. VI Congreso Ibérico y IV Congreso Iberoamericano de Ciencias y Técnicas del Frío, Madrid, España, 22-24 de febrero, 2012.
- Formats : PDF
View record
-
ENERGY PERFORMANCE OF OFFICE BUILDINGS IN SINGA...
- Author(s) : WONG Y. W.
- Date : 1988
- Languages : English
View record