IIR document
CONVECTIVE COUPLING BETWEEN ZONES AND CORRESPONDING HVAC DEMAND.
Author(s) : DELORME Y., LEBRUN J.
Summary
FOR A LONG TIME CONVECTIVE COUPLING BETWEEN ZONES WAS CONSIDERED ONLY FOR COMFORT. TESTS WERE CARRIED OUT IN ENVIRONMENTAL CHAMBERS, BUT THE MEASUREMENTS WERE NEVER APPLIED TO THE CALCULATION OF CONVECTIVE COUPLING BETWEEN THE DIFFERENT ZONES OF A ROOM. COUPLING BECOMES VERY IMPORTANT IN MULTIZONE OFFICES OR IN VERY HIGH ROOMS. IN OFFICE BUILDINGS, THE MAIN PROBLEM IS THE SIMULTANEOUS REQUIREMENT OF HEATING AND COOLING IN PERIMETER AND CENTRAL ZONES. NEGLECTING COUPLING WOULD LEAD TO OVERESTIMATE THE HEATING LOAD IN THE PERIMETER AND THE COOLING LOAD IN CENTRAL ZONES. IN FACT, THE TEMPERATURES OF THE DIFFERENT ZONES TEND TO EQUALISE. TILL SATISFACTORY TEST DATA ON COUPLING IS AVAILABLE, COMPUTER SIMULATION CAN GIVE A ROUGH ESTIMATION AND PROVIDES SOME EVALUATION OF COUPLING.
Available documents
Format PDF
Pages: 1981-5
This document is to be digitised and will be available within 10 working days
Public price
20 €
Member price*
Free
* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).
Details
- Original title: CONVECTIVE COUPLING BETWEEN ZONES AND CORRESPONDING HVAC DEMAND.
- Record ID : 1983-1498
- Languages: English
- Source: Heat pumps and air circulation in conditioned spaces.
- Publication date: 1983
- Document available for consultation in the library of the IIR headquarters only.
Links
See other articles from the proceedings (37)
See the conference proceedings
Indexing
- Themes: Comfort air conditioning
- Keywords: Office; Heat balance; Climatic chamber; Ventilation; Thermal comfort; Air conditioning
-
Testing of localised ventilation systems in a n...
- Author(s) : ARENS E. A., et al.
- Date : 1991/09
- Languages : English
- Source: Indoor Air - vol. 1 - n. 3
View record
-
Predicted and reported thermal sensation in cli...
- Author(s) : OSELAND N. A.
- Date : 1995/12
- Languages : English
- Source: Energy Build. - vol. 23 - n. 2
View record
-
Modelling the performance of a naturally ventil...
- Author(s) : AXLEY J. W., EMMERICH S. J., WALTON G. N.
- Date : 2002
- Languages : English
- Source: ASHRAE Transactions. 2002 annual Meeting, Honolulu, Hawaii. Volume 108, part 2 + CD-ROM.
View record
-
Investigation study on the heat load and heat s...
- Author(s) : ICHINOSE A., OKUMIYA M., HAYAKAWA A., et al.
- Date : 2008/08
- Languages : Japanese
- Source: Transaction of the Society of Heating, Air-conditioning and Sanitary Engineers of Japan - n. 137
View record
-
Grenzen der thermischen Last bei Fensterlüftung...
- Author(s) : ZEIDLER O.
- Date : 2001/07
- Languages : German
- Source: KI Luft Kältetech. - vol. 37 - n. 7
View record