Correlation to predict conditions that lead to liquid-flooding at compressor start-up as a function of evaporator size and fluid properties.
Author(s) : BRENDEL L. P. M., PRANATHARTHI HARAN S., LIU H., BRAUN J. E., GROLL E. A.
Type of article: IJR article
Summary
Refrigeration cycles with fixed speed compressors cycle on and off to modulate their time averaged cooling capacity. While the cycles are turned off, refrigerant can migrate from the condenser into the colder evaporator. The next start-up process can then pull liquid refrigerant out of the evaporator and into the compressor causing liquid flooding. This phenomenon results in a loss of latent heat for cooling, can undercool the lubricant, and may cause damage to the compression mechanism. The geometric and thermophysical conditions that lead to liquid flooding are poorly understood. Experimental data collected for four refrigerants and three heat exchangers was analyzed for flooding conditions. A correlation was fitted to the experimental data, predicting the experimentally determined charge threshold for flooding with an average deviation of 6.6% and a maximum deviation of 16.7%. Repeating the tests with other heat exchanger types and smaller or larger compressors is suggested as important future work.
Available documents
Format PDF
Pages: 349-356
Available
Public price
20 €
Member price*
Free
* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).
Details
- Original title: Correlation to predict conditions that lead to liquid-flooding at compressor start-up as a function of evaporator size and fluid properties.
- Record ID : 30030914
- Languages: English
- Subject: Technology
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 146
- Publication date: 2023/02
- DOI: http://dx.doi.org/10.1016/j.ijrefrig.2022.11.017
Links
See other articles in this issue (41)
See the source
Indexing
- Themes: Compressors
- Keywords: Compressor; Slugging; Expérimentation; Flooded evaporator; Refrigerant charge; Correlation
-
SIMULATION OF THE CHARACTERISTICS OF A SHELL AN...
- Author(s) : OGARKOV S. E., CEJTLIN Ju. A.
- Date : 1988
- Languages : Russian
- Source: Kholodilnaya Tekhnika - n. 11
View record
-
U turn accumulator: a new design concept.
- Author(s) : PARANJPEY R.
- Date : 2013/11
- Languages : English
- Source: Air Conditioning and Refrigeration Journal, Cold Chain - vol. 4 - n. 3
- Formats : PDF
View record
-
Performance of vapour compression systems with ...
- Author(s) : BELL I. H., GROLL E. A., BRAUN J. E.
- Date : 2011/01
- Languages : English
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 34 - n. 1
- Formats : PDF
View record
-
OIL SEPARATORS: WHEN, WHERE, HOW.
- Author(s) : DOHLINGER M.
- Date : 1991/01
- Languages : German
- Source: Kälte + Klimatechnik (Die) - vol. 44 - n. 1
View record
-
Experimental study on the dynamic characteristi...
- Author(s) : ZHANG G., LI J., GE F.
- Date : 2007/08
- Languages : Chinese
- Source: HV & AC - vol. 37 - n. 201
- Formats : PDF
View record