Counterflow double-pipe heat exchanger analysis using a mixed lumped-differential formulation.

Author(s) : SCOFANO NETO F., COTTA R. M.

Type of article: Article

Summary

Numerical results for heat transfer quantities are presented in terms of the dimensionless governing parameters along the thermal entry region, allowing for critical comparisons against the concurrent flow situation, limiting solutions and engineering-type correlations.

Details

  • Original title: Counterflow double-pipe heat exchanger analysis using a mixed lumped-differential formulation.
  • Record ID : 1992-2652
  • Languages: English
  • Source: International Journal of Heat and Mass Transfer - vol. 35 - n. 7
  • Publication date: 1992/07

Links


See other articles in this issue (4)
See the source