Design and optimization of a two-stage 28 K Joule–Thomson microcooler.

Author(s) : CAO H. S., MUDALIAR A. V., DERKING J. H., et al.

Type of article: Article

Summary

Micro Joule–Thomson (JT) coolers made from glass wafers have been investigated for many years at the University of Twente. After successful realization of a single-stage JT microcooler with a cooling capacity of about 10 mW at 100 K, a two-stage microcooler is being researched to attain a lower temperature of about 30 K. By maximizing the coefficient of performance (COP) of the two-stage microcooler, nitrogen is selected as the optimum working fluid for the first stage and hydrogen as that for the second stage. A dynamic finite-element model is developed for analyzing the cooler performance and to calculate the smallest cooler geometry. The optimized overall cooler dimensions are 20.4 × 85.8 × 0.72 mm for a net cooling power of 50 mW at 97 K at the first stage and 20 mW at 28 K at the second stage. The cool-down time to 28 K is calculated to be about 1.7 h with mass-flow rates of 14.0 mg/s for nitrogen and 0.94 mg/s for hydrogen at steady state. [Reprinted with permission from Elsevier. Copyright, 2011].

Details


Links


See other articles in this issue (6)
See the source