Development of high efficiency cycles for domestic refrigerator-freezer application.

Number: pap. n. 746

Author(s) : YANG M., JUNG C. W., KANG Y. T.

Summary

A high efficiency 2 stage vapour compression cycle is developed for domestic refrigerator-freezer application. The 2 stage refrigeration system consists of two evaporators, two compressors, a condenser, two heat exchangers, expansion valves and a vapour-liquid separator. A new high efficiency cycle is selected depending on the arrangement of evaporators and compressors. The cycle simulation is carried with the refrigerant of R600a. It is found the 2 stage cycle with two serial evaporators and two parallel compressors gives the highest COP. COP of 2 stage cycle with two serial evaporators and two parallel compressors is more than 10.74% COP of 2 stage cycle with two parallel evaporators and two serial compressors.

Available documents

Format PDF

Pages: 6 p.

Available

  • Public price

    20 €

  • Member price*

    Free

* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).

Details

  • Original title: Development of high efficiency cycles for domestic refrigerator-freezer application.
  • Record ID : 30015539
  • Languages: English
  • Source: Proceedings of the 24th IIR International Congress of Refrigeration: Yokohama, Japan, August 16-22, 2015.
  • Publication date: 2015/08/16
  • DOI: http://dx.doi.org/10.18462/iir.icr.2015.0746