Development of high efficiency RAC with R410A.
[In Japanese. / En japonais.]
Author(s) : FUJIVAYASHI K., MIYAZAKI N., NONAKA M., et al.
Summary
HCFC-22 has been widely used as a refrigerant in air conditioners. According to the Montreal Protocol for ozone layer protection, phaseout has to be done by 2030. The azeotropic refrigerant mixture R410A is selected as the alternative refrigerant for HCFC-22. Performance improvement and reliability securing is necessary for room air conditioners using R410A. The performance was improved by improvements in the heat exchanger, compressor and inverter circuit. Reliability was achieved through improvements in the compressor and refrigerating circuit.
Details
- Original title: [In Japanese. / En japonais.]
- Record ID : 2006-0386
- Languages: Japanese
- Source: The International Symposium on HCFC Alternative Refrigerants and Environmental Technology 2000: Latest technology for Energy Conservation, Refrigerants and Recycling on Air-Conditioning and Refrigeration Equipment for the 21st century. Proceedings.
- Publication date: 2000/12/07
Links
See other articles from the proceedings (27)
See the conference proceedings
Indexing
-
Themes:
Other air-conditioning equipment;
HCFCs;
Blends - Keywords: R410A; Enhancement; Air conditioner; Variable speed; R22; Substitute; Performance; Refrigerant; Air conditioning; Heat exchanger; Compressor
-
Development of room air conditioners with R410A.
- Author(s) : NAKAMURA Y., HIRANO K., YAMANASHI Y., et al.
- Date : 2000/12/07
- Languages : Japanese
- Source: The International Symposium on HCFC Alternative Refrigerants and Environmental Technology 2000: Latest technology for Energy Conservation, Refrigerants and Recycling on Air-Conditioning and Refrigeration Equipment for the 21st century. Proceedings.
View record
-
Auslegungskriterien und Betriebserfahrungen von...
- Author(s) : DKV, HARTMANN K.
- Date : 1998/11/18
- Languages : German
- Source: DKV-Tagungsbericht 25. 1998, Würzburg.
View record
-
Reliability study of compressor for room air co...
- Author(s) : IIZUKA T., ISHIYAMA A., HATA H., SATO K., FUJIBAYASHI K.
- Date : 1996/07/23
- Languages : English
- Source: Proceedings of the 1996 International Compressor Engineering Conference at Purdue.
View record
-
Comparison of R407C and R410A with R22 in a 10....
- Author(s) : MURPHY F. T., LOW R. E., GILBERT B. E., LINTON J. W., SNELSON W. K., HEARTY P. F.
- Date : 1995/10/23
- Languages : English
- Source: Stratospheric Ozone Protection for the 90's. 1995 International CFC and Halon Alternatives Conference & Exhibition. Conference proceedings.
View record
-
Room air conditioner.
- Author(s) : NAKAYAMA M., SUMIDA Y., TANIMURA Y.
- Date : 1997/05
- Languages : Japanese
- Source: Refrigeration - vol. 72 - n. 835
View record