Design criteria and operating experience with R410A: refrigerating units for air conditioning.
Auslegungskriterien und Betriebserfahrungen von R410A: Kälteaggregaten für die Klimatechnik.
Author(s) : DKV, HARTMANN K.
Summary
R410A was successfully substituted for R22 in compact air-conditioning plants. System design requirements were mastered, and advantages such as small heat-transfer surfaces were obtained. Assembly problems and requirements can be known and solved through suitable training of personnel.
Details
- Original title: Auslegungskriterien und Betriebserfahrungen von R410A: Kälteaggregaten für die Klimatechnik.
- Record ID : 2000-2137
- Languages: German
- Source: DKV-Tagungsbericht 25. 1998, Würzburg.
- Publication date: 1998/11/18
- Document available for consultation in the library of the IIR headquarters only.
Links
See other articles from the proceedings (67)
See the conference proceedings
Indexing
-
Themes:
Other air-conditioning equipment;
HCFCs;
Blends - Keywords: Refrigerating circuit; R410A; Air conditioner; Design; R22; Substitute; Performance; Refrigerant; Air conditioning
-
Replacements for HCFC-22 in air conditioning an...
- Author(s) : SPATZ M. W.
- Date : 2000/07/25
- Languages : English
- Source: Proceedings of the 2000 International Refrigeration Conference at Purdue.
View record
-
Development of high efficiency RAC with R410A.
- Author(s) : FUJIVAYASHI K., MIYAZAKI N., NONAKA M., et al.
- Date : 2000/12/07
- Languages : Japanese
- Source: The International Symposium on HCFC Alternative Refrigerants and Environmental Technology 2000: Latest technology for Energy Conservation, Refrigerants and Recycling on Air-Conditioning and Refrigeration Equipment for the 21st century. Proceedings.
View record
-
Practical evaluation of R410A system materials ...
- Author(s) : IIZUKA T., YAMADA H., SUGANO T., et al.
- Date : 1998/11/26
- Languages : Japanese
- Source: Proceedings of the International symposium on HCFC alternative refrigerants '98: latest technology for higher performance and higher efficiency air conditioning and refrigeration equipment to the 21st century.
View record
-
Comparison of R407C and R410A with R22 in a 10....
- Author(s) : MURPHY F. T., LOW R. E., GILBERT B. E., LINTON J. W., SNELSON W. K., HEARTY P. F.
- Date : 1995/10/23
- Languages : English
- Source: Stratospheric Ozone Protection for the 90's. 1995 International CFC and Halon Alternatives Conference & Exhibition. Conference proceedings.
View record
-
Reliability study of compressor for room air co...
- Author(s) : IIZUKA T., ISHIYAMA A., HATA H., SATO K., FUJIBAYASHI K.
- Date : 1996/07/23
- Languages : English
- Source: Proceedings of the 1996 International Compressor Engineering Conference at Purdue.
View record