Developments of minimizing oil carry over in ammonia refrigerating systems.
[In Dutch. / En néerlandais.]
Author(s) : HERFST J. F.
Type of article: Article
Summary
The article describes the need for a suitable oil recovery system in refrigeration equipment using ammonia, especially for screw compressors where a large quantity of oil is in circulation. Developments in improving oil separation is highlighted.
Details
- Original title: [In Dutch. / En néerlandais.]
- Record ID : 1994-2241
- Languages: Dutch
- Source: Koude & Luchtbehandeling - vol. 86 - n. 12
- Publication date: 1993/12
- Document available for consultation in the library of the IIR headquarters only.
Links
See other articles in this issue (1)
See the source
Indexing
-
Themes:
Compression systems;
Compressors - Keywords: Enhancement; Design; Recovery; Ammonia; Refrigerating plant; Oil; Development; Screw compressor
-
Ocena efektywnosci energetycznej sprezarkowych ...
- Author(s) : PALIWODA A.
- Date : 2005
- Languages : Polish
- Source: Technika Chlodnicza i Klimatyzacyjna - vol. 12 - n. 9
- Formats : PDF
View record
-
Improvement on the energy output controller of ...
- Author(s) : SUI J.
- Date : 1997/10
- Languages : Chinese
- Source: HV & AC - vol. 27 - n. 117
View record
-
Vapour compression refrigerating machines.
- Author(s) : PANNO G.
- Date : 1994
- Languages : Italian
- Source: Industria & Formazione - vol. 18 - n. 5
View record
-
Screw compressor.
- Author(s) : TSUBOI N.
- Date : 1995/05
- Languages : Japanese
- Source: Refrigeration - vol. 70 - n. 811
View record
-
Improving lubricating systems of rubbling sub-a...
- Author(s) : DEN G. N., SHISHKIN Ju. P., MAKSIMOV V. V., SHAGAEV I. H.
- Date : 1994
- Languages : Russian
- Source: Kholodilnaya Tekhnika - n. 3
View record