IIR document
Economic analysis of air-cooled chiller with advanced heat rejection.
Author(s) : YU F. W., HO W. T., CHAN K. T., et al.
Type of article: Article, IJR article
Summary
This study analyses economic benefits of an air-cooled chiller retrofitted with advanced heat rejection features. The rated capacity was 282?kW and operating variables were monitored comprehensively to develop random forest models. The top five variables to ensure model accuracy were identified. Electricity savings were predicted by the models with 3 advanced operating modes: variable speed control for condenser fans with an adjustable condensing temperature (the VSD mode), mist precooling of condenser air (the Mist mode), and their composites (the VSD?+?Mist mode). The integrated part load value (IPLV) was 2.90, 3.31, 2.93 and 3.34 for the normal mode, VSD mode, Mist mode, and the VSD?+?Mist mode, respectively. For a chiller system serving an office building, the VSD mode gave the highest economic benefit with a simple payback of 10.83 yrs and an internal rate of return of 4.38% over a 15-yr life cycle.
Available documents
Format PDF
Pages: 54-64
Available
Public price
20 €
Member price*
Free
* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).
Details
- Original title: Economic analysis of air-cooled chiller with advanced heat rejection.
- Record ID : 30019833
- Languages: English
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 73
- Publication date: 2017/01
Links
See other articles in this issue (21)
See the source
Indexing
-
Themes:
Evaporators, condensers and other heat exchangers;
Chillers - Keywords: Heat; Economy; Variable speed; Fan; Control (automatic); Air-source system; Model; Condenser
-
Optimum condenser fan staging for air-cooled ch...
- Author(s) : YU F. W., CHAN K. T.
- Date : 2005/10
- Languages : English
- Source: Applied Thermal Engineering - vol. 25 - n. 14-15
View record
-
Verflüssigungsdruckregelung mit drehzahlgeregel...
- Author(s) : NESSEL R.
- Date : 1997/05
- Languages : German
- Source: Kälte + Klimatechnik (Die) - vol. 50 - n. 5
View record
-
Leistungsregelung von Verdichtern und Verflüssi...
- Author(s) : FREDSTED J., JUEL O.
- Date : 2004/10
- Languages : German
- Source: KI Luft Kältetech. - vol. 40 - n. 10
View record
-
Method and apparatus for controlling evaporator...
- Author(s) : IOSIFESCU C.
- Date : 2002
- Languages : English
- Source: Ann. Univ. Dunarea Jos Galati, IV - vol. 16
View record
-
Low charge ammonia air-cooled chillers with mic...
- Author(s) : ALOISIO F., DEL GOBBO G.
- Date : 2011/04/14
- Languages : English
- Source: 4th Conference on Ammonia Refrigeration Technology. Proceedings: Ohrid, North Macedonia, April 14-16, 2011.
- Formats : PDF
View record