Effect of room modelling and sensor position on performance assessment of variable air volume control systems.
Author(s) : RIEDERER P., DEXTER A. L.
Type of article: Article
Summary
Variable air volume (VAV) systems are commonly used for air conditioning in buildings. The testing of different control strategies and controllers for this application has been a main concern in several simulation studies. In these simulations much attention has been paid to the accuracy of the models of the VAV system while very simple models are often used at the room level. These room models assume that the air in the room is perfectly mixed, even when the prevailing conditions are not at all homogeneous. Another important issue when testing controllers is the method used to assess the control performance. Since it makes no sense to use very detailed room models, if the method of performance assessment is insensitive to the way in which the room is modelled, both issues must be treated simultaneously. The paper considers the problem of assessing the performance of VAV systems that use ceiling diffusers. The study includes the development of a convection model for a room. Its complexity is reduced to a minimum to allow detailed dynamic simulation of a whole building, complete with its VAV system and other building services (e.g., sun-blinds, lighting, etc.). Since airflow in a room depends strongly on the type of diffuser that is used, the study is carried out for both round and slot diffusers. Results are presented that show that the room model and the position of the sensor affect the performance in different ways depending on the diffuser type and the operating mode. It is concluded that there are only small differences in terms of thermal comfort but significant differences in terms of overall energy consumption. The effect of sensor position on energy consumption is found to be a function of steady state temperature differences.
Details
- Original title: Effect of room modelling and sensor position on performance assessment of variable air volume control systems.
- Record ID : 2004-2930
- Languages: English
- Source: Build. Serv. Eng. Res. Technol. - vol. 24 - n. 1
- Publication date: 2003/03
- Document available for consultation in the library of the IIR headquarters only.
Links
See other articles in this issue (2)
See the source
-
Experimental study of thermal environment and c...
- Author(s) : MARIPUU M. L.
- Date : 2007/06/10
- Languages : English
- Source: Clima 2007. WellBeing Indoors. Proceedings of the 9th REHVA World Congress [CD-ROM + Abstract book].
View record
-
Simplified modelling of variable refrigerant fl...
- Author(s) : FILFLI S., MARCHIO D.
- Date : 2006/02
- Languages : English
- Source: Eurovent-Cecomaf, Rev. - n. 83
View record
-
Analysis of heating energy consumption of a VRV...
- Author(s) : XUE W., LIU C., CHEN P.
- Date : 2001/08
- Languages : Chinese
- Source: HV & AC - vol. 31 - n. 141
View record
-
Rating modern office air conditioning systems o...
- Author(s) : LEDERER S., ROTH H. W., HANDEL C.
- Date : 1993/07
- Languages : German
- Source: Klima Kälte Heiz. - vol. 21 - n. 7-8
View record
-
A study on a new performance rating approach fo...
- Author(s) : SU X. G., LIU Q.
- Date : 2014/07/14
- Languages : English
- Source: 2014 Purdue Conferences. 3rd International High Performance Buildings Conference at Purdue.
- Formats : PDF
View record