Summary
In order to measure and quantitatively analyse the accuracy degree of investigation methods, surveys the summer energy consumption of 69 split air conditioners in 27 households in Beijing in 2011, simultaneously using questionnaires, power meter data splitting and direct measuring methods, and compares and analyses the results of these methods. The results show that the error of the questionnaire method is the largest, whose absolute error to the investigation values for a single household is from -133 to + 1 111 kWh and the average relative error is 23%; the accuracy of the power meter data-splitting method is higher, whose absolute error is from - 45 to + 114 kWh and average relative error is 6.4 % ; the accuracy of the improved power meter data-splitting method is even higher, the average relative error is only 1.7%, and it can meet the needs for investigating air conditioning energy consumption in residential buildings.
Available documents
Format PDF
Pages: 30-33
Available
Public price
20 €
Member price*
15 €
* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).
Details
- Original title: [In Chinese. / En chinois.]
- Record ID : 30009980
- Languages: Chinese
- Source: HV & AC - vol. 43 - n. 276
- Publication date: 2013/04
Links
See other articles in this issue (7)
See the source
Indexing
- Themes: Comfort air conditioning
- Keywords: Split system; Energy consumption; China; Residential building; Expérimentation; Survey; Air conditioning
-
Survey and inspired thoughts of air-conditionin...
- Author(s) : LI Z., JIANG Y.
- Date : 2008/02
- Languages : Chinese
- Source: HV & AC - vol. 38 - n. 208
- Formats : PDF
View record
-
Energy performance comparison of heating and ai...
- Author(s) : WANG W., ZHANG J., JIANG W., et al.
- Date : 2011/06
- Languages : English
- Source: HVAC&R Research - vol. 17 - n. 3
View record
-
Energy consumption except heating of large-scal...
- Author(s) : FENG K., TIAN X., WEI Y.
- Date : 2013/04
- Languages : Chinese
- Source: HV & AC - vol. 43 - n. 276
- Formats : PDF
View record
-
Energy consumption investigation and analysis o...
- Author(s) : LIAO R.
- Date : 2012/04
- Languages : Chinese
- Source: HV & AC - vol. 42 - n. 262
- Formats : PDF
View record
-
Performance evaluation of multi-split type air-...
- Author(s) : HIRAOKA M., HIROMOTO S. I., KOMODA H., et al.
- Date : 2011/04
- Languages : Japanese
- Source: Transactions of the Society of Heating, Air-Conditioning and Sanitary Engineers of Japan - n. 169
View record