Energy performance of indirect evaporative cooling in chilled ceiling applications in maritime temperate climates.
Author(s) : COSTELLOE B., FINN D.
Summary
Evaporative cooling has limited applications in maritime, temperate, climates due to the low levels of cooling water availability which result, when low temperature (5 to 8 °C), convection based, building cooling systems are used. However, the success of "high temperature" radiant cooling, in the form of chilled ceilings, has prompted a review of evaporative cooling in maritime, temperate, conditions. In order to maximize evaporative cooling availability, however, in this application, it is necessary to achieve low wet bulb temperature approach conditions, at viable levels of primary energy consumption. The paper presents the results of experimental research into the energy performance of an evaporative cooling test rig, designed to maximize cooling water availability at the temperatures required for chilled ceilings (14 to 18 °C). Results are compared with typical energy efficiencies of conventional, refrigeration based, building cooling systems. A significant potential for improved energy performance is shown.
Available documents
Format PDF
Available
Public price
20 €
Member price*
Free
* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).
Details
- Original title: Energy performance of indirect evaporative cooling in chilled ceiling applications in maritime temperate climates.
- Record ID : 2004-2415
- Languages: English
- Source: 21st IIR International Congress of Refrigeration: Serving the Needs of Mankind.
- Publication date: 2003/08/17
Links
See other articles from the proceedings (398)
See the conference proceedings
Indexing
-
Kühldecken ohne Kältemaschine Betreiben.
- Author(s) : SPRECHER P., BORTH J., NIESSEN R.
- Date : 2000/11/22
- Languages : German
- Source: DKV-Tagungsbericht Bremen. 2000.
View record
-
Predicting thermal performance of a closed-wed ...
- Author(s) : GAN G., RIFFAT S. B.
- Date : 1999
- Languages : English
- Source: Build. Serv. Eng. Res. Technol. - vol. 20 - n. 4
View record
-
Chilled ceilings: an ecological cooling system ...
- Author(s) : OLIVEIRA A., FACÃO J., AFONSO C., et al.
- Date : 2000/07/09
- Languages : English
- Source: Air distribution in rooms: ventilation for health and sustainable environment. Roomvent 2000. Proceedings of the 7th international conference.
View record
-
Cooling-tower piping: problems and solutions.
- Author(s) : BRUSHA R. F.
- Date : 2003/08
- Languages : English
- Source: HPAC Engineering - vol. 75 - n. 8
View record
-
Planungsaspekte von Verdunstungskühlern für Kli...
- Author(s) : STURIES H., PANNENBORG J.
- Date : 2006/04/14
- Languages : German
- Source: CCI.Print - n. 5
- Formats : PDF
View record